BEST AVAILABLE CONTROL TECHNOLOGY DETERMINATION DATA SUBMITTED TO THE
CALIFORNIA AIR POLLUTION CONTROL OFFICERS ASSOCIATION BACT CLEARINGHOUSE

Equipment or Process: Spray Booths Revision: 3.0
Equipment Rating: All Date 07/18/00
Project Name & Description A/C Issue Date & ARB File No. BACT AND CORRESPONDING EMISSION CONTROL LEVELS
VOC/HC NOx SOx CO PM/PM10
Toter

Plastic parts coating operation using low-VOC coatings, HVLP spray guns in a painting booth, and an enclosed spray gun cleaner.
12/16/99

(A/C No.: C-43-13-0)

A340-957-00

District Contact:
George Heinen

San Joaquin Valley Unified APCD
(559) 230-5909
george.heinen@valleyair.org
Low-VOC coating, HVLP spray guns in paint booth, and an enclosed spray gun cleaner. VOC limit of 1.09 lb VOC/gallon (less water and exempt compounds). Throughput limited to 45 gallons/day and 16,425 gallons/year

No limit
       
McDonald Mfg. Inc.

M&W dry-filter, bench type spray booth using enamel to coat metal parts.
n.d.

(A/C No.: 352478)

A340-928-00

District Contact:
Amir Dejbakhsh
South Coast AQMD
(909) 396-2618
adejbakhsh@aqmd.gov
Use of Regulation XI compliant materials

667 lbs/month VOC facility wide
(Equivalent to compliance with Regulation XI)
       
Time Aviation Services, Inc.

Two M&W dry-filter automotive spray booths using aerospace coatings such as protective coatings and lacquer thinners to coat large and small aircraft parts.
6/18/99

(A/C No.: 353357

A340-927-00

District Contact:
Amir Dejbakhsh
South Coast AQMD
(909) 396-2618
adejbakhsh@aqmd.gov
Use of Regulation XI compliant materials

No emission limit, but booth shall not use more than 3 gals/day
(Equivalent to compliance with Regulation XI)
       
Cannon Safe

Custom dry-filter, floor type spray booth using topcoat to coat metal parts
n.d.

(A/C No.: 352660)

A340-926-00

District Contact:
Amir Dejbakhsh
South Coast AQMD
(909) 396-2618
adejbakhsh@aqmd.gov
Use of Regulation XI compliant materials

667 lbs/month VOC facility wide
(Equivalent to compliance with Regulation XI)
       
Artisan Resources

Binks model FFF-8-7-T-LH dry-filter, floor type spray booth using topcoat, primer, and lacquer to coat plastic parts
n.d.

(A/C No.: 352716)

A340-925-00

District Contact:
Asha Rawal
South Coast AQMD
(909) 396-2506
arawal@aqmd.gov
Use of Regulation XI compliant materials

667 lbs/month VOC facility wide
(Equivalent to compliance with Regulation XI)
       
DA/PRO Rubber Inc.

Binks model BF-31/2-6-T-B bench type spray booth used to coat rubber parts. Chemlock 205, Chemlock 233, Chemlock 607, Chemlock 5150, SWS primer 418, and TY PLY BN are the coatings used in the spray booth.
7/30/99

(A/C No.: 356063)

A340-924-00

District Contact:
Belinda C. Wan
South Coast AQMD
(909) 396-2532
bwan@aqmd.gov
No control

No emission limit, but booth shall not use more than 200 gallons coating per year
       
Arbek Manufacturing, Inc

Dry filter conveyorized spray booth use to coat wood furniture using topcoat, sealer, acetone-based sealer, high solids stain, and low solids stain
5/26/99

(A/C No.: 347744)

A340-914-00

District Contact:
Ravi Bhatia
South Coast AQMD
(909) 590-1629
rbhatia@aqmd.gov
Super-low VOC coatings with equivalent reduction to an air pollution control system with 85.5% overall control

346 lbs/day VOC facility wide limit
       
Wonderies Collision Center

Blowtherm model System 2000 dry-filter spray booth use to coat motor vehicle auto bodies with primer, primer surfacers, basecoats and clearcoats venting to a 5 hp exhaust fan with a total flow rate of 10,000 scfm
7/1/99

(A/C No.: 354640)

A340-913-00

District Contact:
Jeanne Pandes Villacorte
South Coast AQMD
(909) 396-2621
jpandes_villacorte@aqmd.gov
Envirocure/Blowtherm haptite concentrator/adsorber and catalytic oxidizer

22 lbs/day VOC facility wide limit (22 lb/day represents threshold above which add-on controls are required for enclosed automotive downdraft-type booths)
       
Wonderies Collision Center

Blowtherm model Ultra Prep 9220T dry-filter spray booth use to spray motor vehicle auto bodies, using waterborne primers, primer surfacers and sealers venting to a 15 hp blower with a total flow rate of 26850 scfm
7/1/99

(A/C No.: 352922)

A340-912-00

District Contact:
Jeanne Pandes Villacorte
South Coast AQMD
(909) 396-2621
jpandes_villacorte@aqmd.gov
Equivalent control to Rule 1151 VOC limits and transfer efficiency requirements

22 lbs/day VOC facility wide limit (22 lb/day represents threshold above which add-on controls are required for enclosed automotive downdraft-type booths)
       
Kal-Gard Coating & Mfg., E/M Corp.

Nine Binks, Devilbiss & Bleeker dry-filter bench and floor-type spray booths used to coat aerospace fasteners, each vented to a different inle fan having a total of 200 hp and a total flow rate of 40,000 scfm
5/28/97

(A/C No.: 328050-55, 328058-59, 328061)

A911-340-00

District Contact:
Rene Loof
South Coast AQMD
(909)396-2544
rloof@aqmd.gov
M&W, zeolite concentrator is use with seven beds venting a permanent total enclosure with 9 spray booths and 5 ovens. The beds are desorbed with hot air and vented through a thermal oxidizer at 1400 F.

216 lb/day VOC facility limit
       
Sierra Aluminum

Four identical Tellkamp System Inc. model 3C413, dry-filter floor-type spray booths used to coat aluminum extrusions, vented by five 91 hp total inlet blowers with a flow rate of 10,000 scfm
9/26/89

(A/C No.: 203452)

A340-910-00

District Contact:
Knut Beruldsen
South Coast AQMD
(909) 396-3136
kberuldsen@aqmd.gov
Tellkamp Systems Inc. regenerative thermal oxidizer with two ceramic saddle beds vents four enclosed, conveyorized spray booths, one flash-off tunnel, and one bake oven

66 lb/day
(Assumed 98% destruction efficiency)
       
US Ordnance

Brinks, Bleeker Bros., Beattie, 6 dry filter enclosed conveyorized spray booths use to coat military ordnance with high VOC primer, pretreatment coatings, and topcoats
11/24/92

(A/C No. 273236)

A340-906-99

District Contact:
Bill Milner
South Coast AQMD
(909) 396-2553
bmilner@aqmd.gov
Adwest Technologies, Inc. regenerative thermal oxidizer with a 1.3 MMBtu/hr natural gas-fired stand-by burner

30 lbs VOC/day
       
Barry Controls

Tellkamp Systems dry filter, 3 bench top and 1 open faced floor type spray booths used to coat shock and noise damping system with adhesive bonding primers and rubber-to-metal bonding.
12/17/92

(A/C No. 272587)

A340-905-99

District Contact:
Bill Milner
South Coast AQMD
(909) 396-2553
bmilner@aqmd.gov
Tellkamp Systems regenerative thermal oxidizer with a 700,000 Btu/hr natural gas-fired burner and a 1.3 MMBtu/hr stand-by burner.

440 lb VOC/month
       
Huck International - Deutsch Operations

Four Spray King, Econo, Industrial Systems, dry filter, open-faced floor-type spary booths used ot coat aerospace fasteners ventilated by one inlet fan wihcih also ventilates three ovens.
n.d.

(A/C No. 298582)

A340-901-99

District Contact:
Rene Loof
South Coast AQMD
(909) 396-2544
rloof@aqmd.gov
Tellkamp Systems regenerative thermal oxidizer with a 1.6 MMBtu/hr natural gas-fired burner and a 3 MMBtu/hr stand-by burner

59 lbs VOC/day
       
Bristol Fiberlite Industries

Four Dial-a-Temp dry filter floor type spray booths use to coat fiberglass skylight domes with polyester resin and galcoat.
5/28/97

(Application no. 324505)

A340-900-99

District Contact:
Desh Jain
South Coast AQMD
(909) 396-2555
djain@aqmd.gov
Ship & Shore Concentrator consisting of three resin spray stations and one gel coat spray station are cented to the rotary carbon adsorber concentrator. The thermal oxidizer has a 1.6 MMBtu/hr natural gas-fired burner

264 lb/day VOC
       
Certified Enameling Inc.

Six Custom made dry filter floor type spray booths use to coat architectural aluminum extrusions vented by using recirculation blowers only.
9/17/97

(A/C No. 331055)

A340-899-99

District Contact:
Wilma Wilson
South Coast AQMD
(909) 396-2444
wwlison@aqmd.gov
Wastech Controls & Engineering Direct-flame Afterburner with a 8 MMBtu/hr natural gas-fired burner and consisting of a thermal oxidizer venting six spray booths and zone 1 of a drying oven

420 lbs/day VOC facility limit
       
Douglas Products Division

Custom made dry filter floor type spray booth use to coat aerospace skins, rails, and fasteners vented to four inlet fans with a total of 22.5 hp and 120 filters.
3/30/94

(Application no. 287160)

A340-898-99

District Contact:
Bijan Ataian
South Coast AQMD
(909) 396-2454
bataian@aqmd.gov
Durr, Concentrator consisting of 2 rotary zeolite concentrators with thermal oxidizer venting an enclosed, non-conveyorized spray booth and flash-off area

No Limit
       
Crown City Plating

Custom made dry filter floor type spray booth used to coat metal parts venting to a 20 hp exhaust blower.
7/1/91

(Application no. 249798)

A340-894-99

District Contact:
Wilma Wilson
South Coast AQMD
(909) 396-2444
wwlison@aqmd.gov
Hirt Direct-Flame Afterburner with a 2.8 MMBtu/hr natural gas-fired burner venting one enclosed, conveyorized spray booth and oven.

No limit
       
Kaiser Marquardt

Bleeker Brothers dry filter floor type spray booth use to coat metal ordnance parts venting to a 10 hp inlet fan.
11/8/88

(Application no. 176076)

A340-893-99

District Contact:
Tom Liebel
South Coast AQMD
(909) 396-2554
tliebel@aqmd.gov
Hirt Direct-Flame Afterburner with a 6,357,030 Btu/hr natural gas-fired burner venting one conveyorized spray booth, flush tunnel and oven.

No limit
       
Sandberg Furniture Mfg. Co. Inc.

Coating and drying system: Mid State Industrial, Inc. automatic spray booth with an ultraviolet cure section and a 500 Btu/hr natural gas-fired oven, vented by a 5 hp blower.
2/21/97

(Application no. 323199)

A340-889-99

District Contact:
Alice Santos
South Coast AQMD
(909) 396-2601
asantos@aqmd.gov
Use of a super clean material containing no more than 5% by wt. VOC is used as sealers and topcoats.

1689 lb/day (facility wide)
       
Frontier Aluminum

Four Tellkamp System Inc. models 10810 and 12810, dry filter floor-type spray booths use to coat aluminum extrusions, each spray booth is vented by an inlet blower at 14135 scfm. Non-compliant coatings are applied in all booths.
4/25/89

(A/C No. 183205-208)

A340-887-99

District Contact:
Rene Loof
South Coast AQMD
(909) 396-2554
rloof@aqmd.gov
Tellkamp Systems Inc. regenerative thermal oxidizer with two ceramic saddle beds venting four open conveyorized spray booths, and one flash-off tunnel and one bake oven

68 lb/day VOC
       
International Extrusion

Two identcal custom made dry filter floor type spray booths use to coat aluminum extrusions, each spray booth is vented by an exhaust blower at 14300 scfm. Coatings automatically applied.
9/2/93

(A/C No. 280817)

A340-887-99

District Contact:
Ken Matsuda
South Coast AQMD
(909) 396-2656
kmatsuda@aqmd.gov
Tellkamp, regenerative thermal oxidizer with two ceramic saddle beds venting two enclosed conveyorized spray booths, one flash-off area and one oven

68 lb/day VOC
       
Northrop-Crumman

Two identical Devilbiss model XCF 400, dry filter floor type spray booths used to coat aircraft assemblies, including manual application of noncompliant coatings. Booths vented by two inlet blowers.
2/25/91

(A/C No. 228182)

A340-883-99

District Contact:
Todd Iwata
South Coast AQMD
(909) 396-2574
tiwata@aqmd.gov
VIC regenerative adsorber with two 12' diameter beds venting two enclosed, non-conveyorized spray booths, two solvent recovery tanks and one oven

414 lb/day
Permit requires 90% recovery for adsorber
       
Bassi Distribution Company

Automated finishing system consisting of 1) Liberty model L-10-15-8 paint spray booth, 2) Conveyor transferring pallets to drying oven, 3) Electric infrared drying oven at 200 F max, 4) DeVilbiss HVLP spray guns.
11/19/98

(A/C no. 9617)

A340-860-98

District Contact:
Mary Giraudo
Monterey Bay Unified APCD
(831) 647-9411
MGiraudo@mbuapcd.org
Low VOC coating usage Sherwood 2400 marking paint (1.78 lb VOC/gal), 3.5 lb/gal VOC content for other coatings, HVLP spray guns, in conjunction with coating usage limits

137 lb/day VOC
       
Bob Wondries Ford

Devilbiss, model no. 2000-0.97 automotive paint spray booth with 5 hp exhaust fan and gas-fired heater with 970,000 MMBtu/hr burner
2/4/98
(P/O no. F11713; no A/C issued))

A340-841-98

District Contact:
Jeanne Pandes Villacorte
South Coast Air Quilty Management District
(909) 396-2621
jpandes_villacorte@aqmd.gov
ITW Devilbiss Envirocure control system consisting of primary and secondary haptitle absorption bed and 600,000 catalytic oxidizer

900 lbm/mo
       
Auto Ventures, Inc., Acme Autoworks DBA

Devilbiss, model no. 2000-0.97 automotive paint spray booth with 5 hp exhaust fan and gas-fired heater with 970,000 MMBtu/hr burner
3/19/98
(P/O no. F12707; no A/C issued)

A340-840-98

District Contact:
Jeanne Pandes Villacorte
South Coast Air Quilty Management District
(909) 396-2621
jpandes_villacorte@aqmd.gov
ITW Devilbiss Envirocure control system consisting of primary and secondary haptitle absorption bed and 700,000 catalytic oxidizer

667 lbm/mo
       
Up-Right, Inc.

Coating operation for metal parts in an Air Filtration model TSD-4024 paint spray booth (40' X 20' X 20') with dry filters and 7.5 hp exhaust fan
12/9/97

(A/C no. C-1350-11-0)

A340-815-98

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
Coatings with VOC content less than 2.3 lb/gal as applied

20 lbm/day
7300 lbm/yr
      HVLP gun applicator, dry filters, and a 7.5 hp exhaust fan

4.4 lbm/day
1606 lbm/yr
American Door Manufacturing

Wood products coating operation (doors) - non-continuous batch coating operation
11/21/96

(A/C no. N-1084-3-1)

A340-811-97

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
HVLP or equivalent application equipment and coatings with a VOC content 0.68 lbm/gal for water based pigmented primers and 1.62 lbm/gal for water based pigmented topcoats

15.4 lbm/day
       
Prestigious Auto Body

Auto body shop with two automotive type paint spray booths and two automotive type preperation stations, equipped with particulate filter system. High transfer HVLP spray guns
12/3/97

(A/C no. 9820)

A340-802-97

District Contact:
Kemal Serdengecti
Santa Barbara County APCD
(805) 961-8875  
HVLP guns, spray booth with particulate filters, low-VOC coatings per APCD Rule 339, enclosed spray gun cleaner

55 lbm/day
       
Harbor Signs

Sign coating operation
12/13/96

(A/C no. N-3535-1-0)

A340-793-97

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
        Enclosed paint spray booth with particulate filters and HVLP application equipment

2.9 lbm/day
California Air National Guard, Fresno

15 bhp electric compressor for HVLP applicator used to coat areospace parts in a JBI model OWSBT-44-5B paint spray booth(44' L x 16' W x 16' H) with dry filters and 10 bhp exhaust fan
1/22/97

(A/C no. C-0216-26-0)

A340-788-97

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
Lowest available VOC content which meets military specifications

20.9 lbm/day and 2000 lbm/yr
      HVLP gun applicator, dry filters and 10 bhp exhaust fan

1.8 lbm/day and 468 lbm/yr (equivalent to 0.003 gr/scf)
Guy Chaddock and Co.

Coating operation equipment modification to increase VOC and PM10 limits for wood coating operation which includes HVLP spray guns, 2 Binks and 2 Viking floor-type, open-face spray booths
3/7/97

(A/C no. S-3006-1-1, -2-1, -3-1, and -4-1)

A340-786-97

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
HVLP spray equipment

250 lbm/day and 10 tons/yr
      HVLP spray gusns and two Binks and two Viking floor-type, open-face spray booths

26.3 lbm/day
American Door Manufacuring

Wood products (doors) coating operation - non-continuous batch coating operation. Operation limited to 21.7 lbm/day VOC
11/21/96

(A/C no. N-1084-2-1)

A340-777-97

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
HVLP or equivalent application equipment and coatings with a VOC content 0.68 lbm/gal for water based pigmented primers and 1.62 lbm/gal for water based pigmented topcoats

21.7 lbm/day
      Enclosed spray booth with exhaust filters and HVLP or equivalent application equipment

5.9 lbm/day
Colonial Van and Storage

Sharpe model 975 HVLP applicator and Herkules model P500 mini enclosed gun cleaner. Operation limited to 3 gal/day coating.
1/2/97

(A/C no. C-2862-1-0)

A340-776-97

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
HVLP spray equipment

10.5 lbm/day
      HVLP spray equipment

2.6 lbm/day
RDW Concepts

Outdoor trailer coating operation for semi-truck trailers
1/2/97

(A/C no. N3771-1-0)

A340-768-97

Distict Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
VOC contents less water and exempt compounds limited to 2.8 and 6.0 lbm/gal for topcoats and pretreatment wash primers

5.6 lbm/day
       
Ray's Truck and Trailer Painting

Spray painting booth for trailers requiring color match with truck cabs. Operation is limited to 54.8 lbm VOC/day
11/27/96

(A/C no. N-3569-2-0)

A340-767-97

District Contact
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
        Enclosed spray booth with exhaust filters and HVLP application equipment

7.3 lbm/day
Tote-A-Shed, Inc.

Shipping/storage container coating operation
9/13/96

(A/C no. C-1686-6-0)

A340-740-97

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-59090  
Coating VOC content of 2.8 lbm/gal less water and exempt compounds, use of HVLP spray equipment, and enclosed spray gun cleaning system

28.3 lbm/day
      Use of an HVLP spray gun

7.1 lbm/day
Creations in Wood, Inc.

3.0 hp Universal model 1088 coating booth for coating wooden cabinets and furniture accessories
9/12/96

(A/C no. C-1686-6-0

A340-734-97

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
HVLP and VOC content limits minus water and exempt cpds: 4.6 lb/gal clear topcoat, 3.2 lb/gal high-solids coating, & 4.6 lb/gal sealers sanding

12.5 lbm/day
       
Environmental Service Products

Spray painting operation of trailers requiring color match with truck cab. Painting conducted in a spray booth.
6/21/96

(A/C no. N-3666-1-0)

A340-727-97

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
HVLP spray guns, VOC content of 3.5 lbm/gal (less water and exempt compounds), and enclosed gun cleaner

80 lbm/day
10 tons/yr
       
Kasco Fab, Inc.

Structural steel fabrication and erection (not in booth)
11/30/95

(A/C no. C-7111-1-1)

A340-705-96

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
Use of water-based coating with 1.2 lbm VOC/gal and 4.05 lbm/solids/gal; use of HVLP spray gun

64 lbm/day
      Use of water-based coating with 1.2 lbm VOC/gal and 4.05 lbm solids/gal; use of HVLP spray gun

27 lbm/day
A-Z Manufacturing

Trailer manufacturing and coating operations limited to 13 gal coating per day
1/4/96

(A/C no. C-2731-1-0)

A340-701-96

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
Safety-Kleen enclosed gun cleaner and water-based coating with 2.85 lbm VOC/gal less water and exempt compounds

30 lbm/day
      HVLP Sharp model 975 spray gun

8.9 lbm/day
Guntert and Zimmerman

Spray painting operations of metal parts and products with speciality coatings
2/2/96

(A/C no. N-380-5-0)

A340-687-96

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
Coating VOC content less than 3.5 lbm/gal less water and exempt compounds, enclosed gun cleaner, and HVLP spray guns

40 lbm/day
       
T.B.M., Inc.

Aircraft refinishing operation with low-VOC coatings, HVLP application equipment, and enclosed gun cleaner; operation limited to 11 gal/day and 1600 gal/yr
11/6/95

(A/C no. S-192-2-0)

A340-679-96

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
Use of low VOC coatings (3.5 lbm/gal) and Hercules GW/R enclosed gun cleaner

No limit
(Equivalent to 38.5 lbm/day)
      Binks MACH 1 HVLP spray gun

No limit
Grundfos Pump Corp.

Coating operation on manufacturing assembly line for circulator pumps
8/22/95

(A/C no. C-5977-0)

A340-678-96

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
Use of water-based coating with 1.9 lbm VOC per gallon less water and exempt compounds

6.2 lbm/day
       
Waste Management of Santa Cruz County

Paint spray operation for metal parts using Econo Paint spray booth model ATDT 36-16-12 with Graco HVLP Nova 1000 spray gun and Gillman water-based enamels
9/6/95
(P/O no. 8141, A/C not issued since this is a discovered source)

A340-671-95

District Contact:
Mary Giraudo
Monterey Bay Unified APCD
(408) 647-9411  
HVLP spray gun and water-based enamel with maximum VOC content of 1.9 lbs/gal Gillman Paint Co.-WM Burgundy water reducible #E2187

137 lbm/day
       
Claude Laval Corporation

Spray painting operation for the manufacture of high-gloss sand separators
8/2/95

(A/C no. C-2096-6-0)

A340-667-95

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
Binks Mach 1 HVLP paint gun, compliant coatings, and Safety Kleen gun cleanser

30 lbm/day
      Spray King model 400 paint spray booth with exhaust filters

2.5 lbm/day
(Equivalent to 95% control efficiency
Fluid Containment, Inc.

Fiberglass Utility pole coating operation
5/4/95

(A/C no. S-1810-7-0)

A340-643-95

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
High-volume, low-pressure (HVLP) application equipment, low VOC coatings limited to no more than 10% VOC, and enclosed equipment cleanup or water-based detergent

90.0 lbm/day
      High-volume, low-pressure (HVLP) application equipment and enclosed paint spray booth with exhaust filters

27.0 lbm/day
Custom Woodcraft

Wood coating operation in two Binks downdraft paint spray booths using
1.2 MMBtu/hr gas-fired heater
12/13/94

(A/C no. C-1283-A-1)

A340-634-95

District Contact:
Dean Carlson
San Luis Obispo Co. APCD
(805) 781-5912  
Low-VOC waterborne wood coatings. Clear topcoasts limited to 275 grams per liter less water exempt compounds. Stains, sealers, pigmented coatings limited to 240 g/l.        
Technicolor-Optical Media Services/Compact Disc Manufacturing

Clearcoat and screen-printing ink and coating application equipment for manufacture of compact discs, wipe cleaning
6/6/94

(A/C # 1311-100)
A340-624-94

District Contact:
Kerby Zozula
Ventura County APCD
(805) 645-1421
Kerby@vcapcd.org
Requirement for use of UV curable inks and coating

wipe cleaning solvent vapor pressure no more than 35 mm Hg
       
Aldila, Inc.

Golf-club shaft coating equipment, including Ransburger electrostatic paint spray guns, with application in a Bleeker paint spray booth having a 7000 cfm exhaust fan (average paint use assumed to be 20 gal/day)
10/29/92

(App. no. 92007)

A340-581-93

District Contact:
Lorenzo Alejandria
San Diego Co. APCD
(619) 694-3322  
Thermal oxidizer

95% capture efficiency and 95% destruction efficiency
       
Edwards Air Force Base

36,000 ft2 hanger-sized spray booth for aircraft up to cargo-sized EC-18 planes with coating use limits of
30 gal/day and
5229 gal/yr
5/7/93

(A/C no. 0127187)

A340-572-92

District Contact:
Tom Paxson
Kern Co. APCD
(805) 861-2593  
Carbon adsorption filterbank with flameionization detector to determine breakthrough

95% adsoprtion efficiency by filter bank with assumed capture rate of 90%
       
Basin Valve Co.

Binks Model PFA-6-7-TLH floor-type, open-face, industrial paint spray booth having dimensions of 6'x7'x4' and used for coating valves with hand-held aerosol cans; exhaust fan rated at 5,600 cfm
10/30/92

(A/C no. 0331002)

A340-563-92

District Contact:
Tom Goff
San Joaquin Valley Unified APCD
(805) 862-5200  
        Andreae filter media dry filters

90% control efficiency
CTL Lighting

Metal Table Lamp Paint Spray Operation
8' x 8' x 8' Binks model no. PFA-8-8-T-LH open front industrial paint spray booth
5/20/92

(A/C no. 0293001)

A340-546-92

District Contact:
Tom Paxson
Kern Co. APCD
(805) 861-2593  
        Dry filters

90% control efficiency for PM10
Midwestern Pipeline Services

Pipe coating, including spraybooth and 7.5 MMBtu/hr oven-fired on natural gas; coatings applied to inside of 40"X40' sections of steel pipe
4/16/91

(A/C no. 5948)

A340-537-92

District Contact:
Greg Solomon
Bay Area AQMD
(415) 749-4715  
5000 cfm B&G Automated Systems afterburner from spray operation and oven

98.5% destruction efficiency
       
Westminster Ceramics Glaze Test Spray Line

Spray booth
12/09/91

(A/C no. 1099036)

A340-500-91

District Contact:
Tom Goff/Joe Ancheta
San Joaquin Valley Unified APCD
(805) 862-5200  
        Stainless steel mesh at booth, centrifugal separator with water spray by California Blowpipe

No limit
(Expected control efficiency of 99%)
Tracor Flight Systems, Incorporated

Bleeker Brothers model no. AT-PL-38 paint spray booth with dimensions of 15' x 12' x 36'
10/23/92

(App. no. 228182)

A340-487-91

District Contact:
Kathy Proffer
Kern County APCD
(805) 862-5200  
        Dayton, 36 inch diagonal fan with 5 hp motor and
34 filter cells holding
68 20" x 20" x 3" RP paint arrester and pads
Northrop Aircraft Divsion

Two coating spray booths with common exhaust duct with continuous VOC emission monitor
10/29/90

(App. no. 228182)

A340-442-90

District Contact:
Ravi Bhatia
South Coast AQMD
(909) 396-2571
rbhatia@aqmd.gov
Carbon absorber and spray guns with at least 65% transfer efficiency

414 lbm/day;
90% control efficiency
       
Chuck Haddad Mitsubishi

Automotive paint spray booth for car dealership
1/31/90

(A/C no. 0182001)

A340-436-90

District Contact:
Tom Goff
Kern Co. APCD
(now the San Joaquin Valley Unified APCD)
(805) 862-5200  
High volume, low pressure spray gun; low VOC coatings to be used when available

2.61 lbm/hr
(Estimated control level of 50%)
       
Northrop B-2 Division
(Palmdale, CA)

Aircraft paint spray facility in aircraft hanger using 2 gal/day of coatings and solvent
5-3-90

(App. no. 224882)

A340-433-90

District Contact:
Ravi Bhatia
South Coast AQMD
(909) 396-2571
rbhatia@aqmd.gov
Filter-type carbon adsorber panels over exhaust air vent

(Expected control of 90%)
       
Frontier Aluminum

Automated coating line for aluminum extrusion; emissions from four spray booths and an oven; coating use limited to
179 lbm/day of coating with no more than
5.5 lbm/gal VOC
4/25/89

(App. no. 186800)

A340-396-90

District Contact:
Permit Services
South Coast AQMD
(909) 396-3385  
Regenerative oxidizer system

95% control
       
Eye Encounter, Inc.

Wood-products coating operation including two paint spray booths, five staining tables, and one
6.5 MMBtu/hr gas-fired drying oven
4/7/89

(App. no. 175616)

A340-394-90

District Contact:
Stacey Ebiner
South Coast AQMD
(909) 396-2504
sebiner@aqmd.gov
Thermal oxidizer

68 lbm/day
       
Energy Coatings Co.

Powder coating booth
5/12/89

(App. no. 183286)

A430-393-90

District Contact:
Permit Services
South Coast AQMD
(909) 396-3385  
        Baghouse

No limit
Comfort Industries

Two filter-type paint spray booths for coating rattan furniture
3/7/89

(App. nos. 170093 and 170094)

A340-383-90

District Contact:
Stacey Ebiner
South Coast AQMD
(909) 396-2504
sebiner@aqmd.gov
None

102 lbm/day
       
Chuck Haddad Mitsubishi

Automotive paint spray booth (for car dealership)
1/31/90

(A/C no. 0182001)

A340-351-90

District Contact:
Tom Goff
Kern Co. APCD
(now the San Joaquin Valley Unified APCD)
(805) 862-5200  
High volume, low pressure (HVLP) spray gun; low VOC coatings to be used when available

20.85 lbm/day
(Equivalent to at least
50% control)
       
Western Steel & Tinplate, Inc.

6000 sheet/hr sheetmetal coating lines and 5 MMBtu/hr natural gas ovens
4/10/89

(App. no. 1931)

A340-341-89

District Contact:
Alex Saschin
Bay Area AQMD
(415) 771-6000  
Direct-flame afterburner

90% capture efficiency with 98.5 percent afterburner control efficiency
       
Arco Solar, Inc.

Spray booth and two in-mold coating units
3/25/88

(A/C no. 0520-3)

A340-273-88

District Contact:
Keith Duval
Ventura Co. APCD
(805) 654-2845
Kerby@vcapcd.org
Catalytic incinerator

95% control efficiency
       
Sierra Tile

Paint spray booth
1/21/88

(A/C no. 8605)

A340-260-88

District Contact:
Aleta Kennard
Sacramento Metropolitan AQMD
(916) 386-6650  
Low VOC coating

250 lbm/day
       
Sundance Spas

Spray booth, styrene spray gun
4/20/87

(App. nos. 153088 thru 153091)

A340-232-87

District Contact:
Stacey Ebiner
South Coast AQMD
(909) 396-2504
sebiner@aqmd.gov
No control

594 lbm/day
      Spray booth and 2 in. thick dry filter

26.1 lbm/day
Airesearch Co.

Spray booth

35 KW oven

42 KW oven

105 KW oven

575 gallon epoxy dip tank
1/8/87

(App. nos. 148655 thru 148658 and 148660)

A340-192-87 thru A340-196-87

District Contact:
Stacey Ebiner
South Coast AQMD
(909) 396-2504
sebiner@aqmd.gov
Carbon adsorption

No limit
(Estimated emission control of 98%)
       
Quality Metal Finishing Corp.

Spray booth
11/12/86

(App. no. 149332)

A340-188-87

District Contact:
Stacey Ebiner
South Coast AQMD
(909) 396-2504
sebiner@aqmd.gov
Use of low-solvent coatings per requirements of Rule 1107

See Rule 1107
       
General Dynamics Corporation

Four curing ovens, rated at 270, 126, 126, and 54 KW for pre-pregnation materials
11/24/86

(App. nos. 145889 thru 145892)

A340-186-87

District Contact:
Stacey Ebiner
South Coast AQMD
(909) 396-2504
sebiner@aqmd.gov
14% VOC limit in resin-impregnation

12 lbm/day
       
General Dynamics Corporation

Coating operation room and curing oven
11/24/86

(App. nos. 145893 and 145894)

A340-185-87

District Contact:
Stacey Ebiner
South Coast AQMD
(909) 396-2504
sebiner@aqmd.gov
No control

No limit
(Estimated emission rate of 8 lbm/day)
      Spray booth

No limit
(Estimated emission control of 90%)
General Dynamics Corporation

Coating operation and two curing ovens
11/24/86

(App. nos. 145895 and 145897)

A340-184-87

District Contact:
Stacey Ebiner
South Coast AQMD
(909) 396-2504
sebiner@aqmd.gov
No control

No limit
(Estimated emissions of
14 lbm/day)
      Spray booth

No limit
(Estimated emission control of 90%)
Crown Cork & Seal Co., Inc.

Aluminum can manufacturing
12/31/85

(A/C no. 30862)

A340-112-86

District Contact:
Judy Cutino
Bay Area AQMD
(415) 771-6000  
Incineration

95% control
       
General Motors - Toyota Joint Venture

Automobile undercoating spray booth
2/22/84

(A/C # 29614)

A410-051-84

District Contact:
Jim Tomich
Bay Area AQMD
(415) 771-6000  
High solids coating, airless spray, incineration

35% control efficiency
       
FMC Corp - San Jose Ordnance

Binks paint spray booth
6/22/82

(A/C # 28310)

A340-012-82

District Contact:
Brain Bateman
Bay Area AQMD
(415) 771-6000  
Binks airless-electrostatic spring of 40% solid paint, spraying by automated robots, and in-line heaters to reduce paint viscosity

190 lbs/day
       
CAPCOA BACT Clearinghouse Source Category - 161 Spray Booths

BEST AVAILABLE CONTROL TECHNOLOGY DETERMINATION DATA SUBMITTED TO THE
CALIFORNIA AIR POLLUTION CONTROL OFFICERS ASSOCIATION BACT CLEARINGHOUSE

Equipment or Process: Steam Generators - Oil Field Revision: 3.0
Equipment Rating: Greater than or equal to 21 MMBtu/hr Date 07/18/00
Project Name & Description A/C Issue Date & ARB File No. BACT AND CORRESPONDING EMISSION CONTROL LEVELS
VOC/HC NOx SOx CO PM/PM10
CalResources LLC

62.5 MMBtu/hr, natural gas- or LPG-fired, C.E. Natco steam generator also being used as a TEOR well-vent gas incinerator
12/4/95

(A/C no. S-1547-75-11)

A310-709-96

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
    C.E. Natco alkali flue-gas SO2 scrubber

95% control
30 ppmv
   
Mobil Exploration and Producing U.S., Inc.

62.5 MMBtu/hr
CE Natco model STOF-50M-1000 steam generator fired on natural gas and waste gas
12/28/92

(A/C nos. 4509 thru 4527)

A310-566-93

District Contact:
J. Steele
Monterey Bay Unified APCD
(408) 647-9411  
  North American low-NOx burner, Westinghouse GPC-1200 oxygen controller, and flue-gas recirculation

30 ppmvd at 3 % oxygen
     
Macpherson Oil Co. Midway-Sunset Field

62.5 MMBtu/hr gas-fired
C.E. Natco steam generator
11/22/91

(A/C no. 4126057)

A310-497-91

District Contact:
Tom Goff or Leonard Scandura
San Joaquin Valley Unified APCD
(805) 862-5200  
  North American low-NOx burner and flue-gas recirculation

0.043 lbm/MMBtu
     
Macpherson Oil Co. Midway-Sunset Field

25 MMBtu/hr gas-fired
C.E. Natco steam generator
11/22/91

(A/C nos. 4126058 and 4126059)

A310-496-91

District Contact:
Tom Goff
San Joaquin Valley Unified APCD
(805) 862-5200  
  North American low-NOx burner and flue-gas recirculation

0.048 lbm/MMBtu
     
ARCO Oil and Gas

Two 62.5 MMBtu/hr gas-fired
C.E. Natco steam generators
11/19/91

(A/C nos. 4007969 and 4007970)

A310-495-91

District Contact:
Tom Goff or
Joe Ancheta
San Joaquin Valley Unified APCD
(805) 862-5200  
  Lo-NOx staged air combustion, flue-gas recirculation, and Thermox excess oxygen controller

0.043 lbm/MMBtu
     
Unocal

Three
62.5 MMBtu/hr gas-fired Struthers steam generators
11/15/91

(A/C nos. 4051179 thru 4051181)

A310-494-91

District Contact:
Tom Goff
San Joaquin Valley Unified APCD
(805) 862-5200  
  NHI PM Lo-NOx and flue-gas recirculation

0.043 lbm/MMBtu
     
Future Energy Co.

Two 62.5 MMBtu/hr gas-fired
C.E. Natco steam generators
10/25/91

(A/C nos. 4231002 and 4231003)

A310-492-91

District Contact:
Tom Goff
San Joaquin Valley Unified APCD
(805) 862-5200  
  North American low NOx burner with flue-gas recirculation ductwork

0.043 lbm/MMBtu
2.71 lbm/hr/unit
     
Nugget Oil Company

62.5 MMBtu/hr gas-fired
C.E. Natco steam generator
10/8/91

(A/C no. 4131003)

A310-481-91

District Contact:
Tom Goff
Kern Co. APCD
(now the San Joaquin Valley Unified APCD)
(805) 862-5200  
  North American low NOx burner with custom fabricated flue-gas recirculation

0.043 lbm/MMBtu
(Equivalent to 57% control efficiency)
     
Mobil E & P U.S. Inc.

Twenty-three
62.5 MMBtu/hr gas-fired
C.E. Natco steam generators
9/5/89

(A/C nos. 4011242 thru 4011264)

A310-344-89

District Contact:
Tom Goff
Kern Co. APCD
(now the San Joaquin Valley Unified APCD)
(805) 862-5200  
  Coen DAF low-NOx burner with ed FGR and Westinghouse/Hagen analyzer/oxygen controller

2.708 lbm/hr per unit
(Equivalent to 0.0433 lbm/ MMBtu or 68% control)
PUC-quality natural gas

0.037 lbm/hr per unit
(Equivalent to 0.00059 lbm/ MMBtu)
  PUC-quality natural gas

0.303 lbm/hr per unit
(Equivalent to 0.00485 lbm/ MMBtu)
ARCO

Conversion of 62.5 MMBtu/hr steam generator from crude oil to natural gas firing
7/12/89

(A/C no. 4007063G)

A310-339-89

District Contact:
Tom Goff
Kern Co. APCD
(now the San Joaquin Valley Unified APCD)
(805) 862-5200  
    Fuel sulfur content limited to more than 0.1 gr/100 scf

No limit
   
ARCO

Conversion of 25.2 MMBtu/hr steam generator from crude oil to natural gas firing
7/12/89

(A/C no. 4007075H)

A310-338-89

District Contact:
Tom Goff
Kern Co. APCD
(now the San Joaquin Valley Unified APCD)
(805) 862-5200  
    Fuel sulfur content limited to more than 0.1 gr/100 scf

No limit
   
Mobil E & P, Inc.

Gas-fired
62.5 MMBtu/hr
C.E. Natco Model STOF-50M-1000 steam generator with North American model 4131G-LNX-FGR burner
4/14/89

(A/C nos. 4481 and 4482)

A310-334-89

District Contact:
Fred Thoits
Monterey Bay Unified APCD
(408) 443-1135  
  Low NOx burner and FGR

40 ppmvd at 3% oxygen
65 lbm/day
(Equivalent to 0.043 lbm/MMBtu)
  No control

5 lbm/day
 
SCPI N. Midway

Ten 62.5 MMBtu/hr gas-fired steam generators
12/31/86

(A/C nos. 4012428 to 4012431 and 4012435 to 4012440)

A310-161-87

District Contact:
Tom Goff
Kern Co. APCD
(now the San Joaquin Valley Unified APCD)
(805) 862-5200  
        Natural gas fuel

0.0043 lbm/MMBtu
Shell California Production, Inc.

Four 62.5 MMBtu/hr C.E. Natco steam generators
8/22/86

(A/C nos. 4013140 thru 4013143)

A310-153-86

District Contact:
Tom Goff
Kern Co. APCD
(now the San Joaquin Valley Unified APCD)
(805) 862-5200  
        Natural gas firing

No limit
(Expected emission level is 4.8 lbm/day/unit)
Shell California Production, Inc.

Eleven 62.5 MMBtu/hr gas-fired steam generators
8/8/86

(A/C nos. 4013123 to 4013128 and 4013135 to 4013139)

A310-149-86

District Contact:
Tom Goff
Kern Co. APCD
(now the San Joaquin Valley Unified APCD)
(805) 862-5200  
    Sodium-based scrubber

0.026 lbm/MMBtu
30% control
   
Shell California Production, Inc.

Six 62.5 MMBtu/hr gas-fired steam generators
8/8/86

(A/C nos. 4013129 to 4013134)

A310-148-86

District Contact:
Tom Goff
Kern Co. APCD
(805) 862-5200  
    Use of PUC-regulated natural gas

0.34 lbm/hr total
   
Shell California Production, Inc.

Two 25.2 MMBtu/hr C.E. Natco steam generators (fired on gas or oil)
6/17/86

(A/C nos. 4013121 and 4013122)

A310-135-86

District Contact:
Tom Goff
Kern Co. APCD
(now the San Joaquin Valley Unified APCD)
(805) 862-5200  
    Scrubber

0.028 lbm/MMBtu heat input
(Equal to 30% control)
  Scrubber

0.030 lbm/MMBtu heat input
(Equal to 70% control)
Unocal

62.5 MMBtu/hr Structhers oil-fired steam generator
12/27/85

(A/C # 4051033E)

A310-102-85

District Contact:
Tom Paxson
Kern County APCD
(Now the San Joaquin Valley Unified APCD)
(805) 861-3682  
    Flue gas scrubber

No control
   
Petro-Lewis Corp.

62.5 MMBtu/hr Struthers oil-fired steam generators with exhaust scrubbers
10/29/85

(A/C # 4052138)

A310-98-85

District Contact:
Tom Paxson
Kern County APCD
(Now the San Joaquin Valley Unified APCD)
(805) 861-3682  
  North American staged combustion burner and reduced firing rate

0.043 lb/MMBtu
Low fuel sulfur content

No limit
Good combustion practice and burner design

0.003 lb/MMBtu
Good combustion practice and burner design

0.005 lb/MMBtu
Petro-Lewis Corp.

62.5 MMBtu/hr Struthers oil-fired steam generators with exhaust scrubbers
10/29/85

(A/C # 4052135, 136, and 137)

A310-097-85

District Contact:
Tom Paxson
Kern County APCD
(Now the San Joaquin Valley Unified APCD)
(805) 861-3682  
  North American staged combustion burner and reduced firing rate

0.12 lb/MMBtu
Anderson 2000 wet scrubber

0.025 lbm/MMBtu
Good combustion practice and burner design

0.0068 lb/MMBtu
Anderson 2000 wet scrubbers

0.028 lbm/MMBtu
Sun Oil Company

30 MMBtu/hr Heater Tech., Inc. Thermotics steam generator served by a scrubber and O2 controller
10/15/85

(A/C # 4014131)

A310-095-85

District Contact:

Tom Paxson
Kern County APCD
(Now the San Joaquin Valley Unified APCD)
(805) 861-3682  
    Scrubber

1.02 lb/day
   
Berry Holding Company

62.5 MMBtu/hr CE Natco steam generator
10/2/85

(A/C # 4016023)

A310-093-85

District Contact:
Tom Paxson
Kern County APCD
(Now the San Joaquin Valley Unified APCD)
(805) 861-3682  
  CE-MHI low-NOx burner including flue gas recirculation

7.5 lb/hr
Neptune AirPol caustic SO2 scrubber, packed tower type

4.45 lb/hr
   
Berry Holding Company

62.5 MMBtu/hr CE Natco steam generator
10/2/85

(A/C # 4016022)

A310-092-85

District Contact:
Tom Paxson
Kern County APCD
(Now the San Joaquin Valley Unified APCD)
(805) 861-3682  
  CE-MHI low-NOx burner including flue gas recirculation

7.5 lb/hr
     
Berry Holding Company

31.5 MMBtu/hr HTI steam generator
10/2/85

(A/C # 4016015B)

A310-091-85

District Contact:
Tom Paxson
Kern County APCD
(Now the San Joaquin Valley Unified APCD)
(805) 861-3682  
  CE-MHI low-NOx burner including flue gas recirculation

6.26 lb/hr
0.20 lb/MMBtu
     
Berry Holding Company

31.5 MMBtu/hr GPI steam generator
10/2/85

(A/C # 4016014A)

A310-90-85

District Contact:
Tom Paxson
Kern County APCD
(Now the San Joaquin Valley Unified APCD)
(805) 861-3682  
  CE-MHI low-NOx burner including flue gas recirculation

6.26 lb/hr
0.20 lb/MMBtu
     
Mobil Oil

Three 62.5 MMBtu/hr Thermotics gas-fired steam generators
9/1/84

(A/C # 4011115, 6, and 7)

A310-064-84

District Contact:
Tom Paxson
Kern County APCD
(Now the San Joaquin Valley Unified APCD)
(805) 861-3682  
Good fuel combustion for HC control

No limit
       
HOPCO
62.5 MMBtu/hr Thermotics crude oil production steam generators
12/4/84

(A/C # 4099002 to 4099013)

A310-059-84

District Contact:
Tom Paxson
Kern County APCD
(Now the San Joaquin Valley Unified APCD)
(805) 861-3682  
    Wet scrubber

97% destruction efficiency
2.1 lbm/hr
  Wet scrubber

70% destruction efficiency
1.7 lbm/hr
Angus Petrotech

62.5 MMBtu/hr oil-filled steam generator w/scrubber & "low NOx" burner
11/29/83

(A/C # 4132002-004)

A310-23-83

District Contact:
Tom Paxson
Kern County APCD
(Now the San Joaquin Valley Unified APCD)
(805) 861-3682  
    Diglycolamine absorbing system for hydrogen sulfide removal

95% control efficiency
61.4 lb/day
   
CAPCOA BACT Clearinghouse Source Category - 162.2 Steam Generators - Oil Field

BEST AVAILABLE CONTROL TECHNOLOGY DETERMINATION DATA SUBMITTED TO THE
CALIFORNIA AIR POLLUTION CONTROL OFFICERS ASSOCIATION BACT CLEARINGHOUSE

Equipment or Process: Storage Tanks Revision: 3.0
Equipment Rating: All Date 07/18/00
Project Name & Description A/C Issue Date & ARB File No. BACT AND CORRESPONDING EMISSION CONTROL LEVELS
VOC/HC NOx SOx CO PM/PM10
Van Waters & Rogers

18 storage tank use to store various commonly used organic liquids prior to distribution to customers. The 18 storage tank include three 3,000, nine 12,000, and six 30,000 gallon tanks.
9/9/99

(A/C No.: 353730)

A360-920-00

District Contact:
Belinda C. Wan
South Coast AQMD
(909) 396-2532
bwan@aqmd.gov
John Zink model ZCS-1-4-20X-3/10 direct-flame thermal oxidizer with two 3.6 MMBtu/hr natural gas-fired burners. One burner is for the passive source and one is for the blower-assisted sources

4 tons/yr VOC emissions facility wide (95% control)
       
Miller Rentaland

One 500 gal aboveground storage tank served by a phase one vapor recovery system and a gasoline dispensing nozzle
9/19/97

(A/C no. C-3160-1-0)

A350-779-97

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
CARB certified Phase I vapor recovery system

6.7 lbm/day
       
Huntington Lake Resort

One 4000 gallon underground storage tank and two gasoline dispensing nozzles used in boat refueling operation
11/20/96

(A/C no. C-2898-1-0)

A350-769-97

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
CARB certification        
City of Coalinga

One 12,000 gallon abovegrund storage tank and one aviation gasoline dispensing nozzle limited to 100,000 gallons/month throughput
12/13/96

(A/C no. C-2969-1-0)

A350-766-97

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
CARB certification        
76 Products Co. (TOSCO)

Crude-oil storage and railcar loading operation, including four 67,000 barrel fixed-roof storage tanks for temporary storage of products prior to railcar loading using six station loading rack with 10,000 bbl/hr output
3/11/96

(A/C no. 4147001 to 007)

A350-718-96

District Contact:
William Lund
Kern Co. APCD
(805) 862-5250  
Enclosed vapor-control system including White Horse thermal oxidizer rated at 33 MMBtu/hr and serving four fixed-roof storage tanks and loading rack

8.71 lbm/hr;
22.60 tons/yr
(Equivalent to 99.65% control efficiency)
       
NAFTEX Holdings, Inc.

15.3 MMBtu/hr vertical, 22 ft. high, air-assisted, waste-gas flare with automatic electronic ignitor, 12" X 24" shield, and a continuous burning propane-fired pilot light to control VOC from three fixed-roof storage tanks
11/29/95

(A/C no. S-1122-4-2)

A350-710-96

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
Steam-assisted combustion or air-assisted combustion when steam is not available; pilot light fired on LPG or natural gas

0.84 lbm/MMBtu
Steam-assisted combustion or air-assisted combustion when steam is not available; pilot light fired on LPG or natural gas

0.0883 lbm/MMBtu
Steam-assisted combustion or air-assisted combustion when steam is not available; pilot light fired on LPG or natural gas

0.60 lbm/MMscf
Steam-assisted combustion or air-assisted combustion when steam is not available; pilot light fired on LPG or natural gas

1.57 lbm/MMBtu
Steam-assisted combustion or air-assisted combustion when steam is not available; pilot light fired on LPG or natural gas

0.020 lbm/MMBtu
5% opacity
Texas Crude Energy, Inc.

Oil production tank battery, including 500 bbl fixed-roof tank, constant-level wash tank, and 500 bbl fixed-roof tank
9/9/93

(A/C nos. S-1864-1-0 and S-1864-2-0)

A350-596-93

District Contact:
Tom Goff
San Joaquin Valley Unified APCD
(805) 862-5200  
Throughput restrictions on wash tank and storage tank at 250 and 100 bbl/day, respectively; pressure/vacuum valve resulting in combined tankage emissions of less than 5 lbm/day

2.1 lbm/day
       
Unocal

Transfer of location and classification for standby use of a 63,000 and 84,000 gallon fixed-roof tanks without vapor controls
7/23/93

(A/C nos. S-1372-133-2 and S-1372-134-2)

A350-592-93

District Contact:
Betty Coppersmith
San Joaquin Valley Unified APCD
(805) 862-5200  
None, but subject to throughput limitation of 10.71 bbl/day and retention time limit of 24 hours

0.68 lbm/day
       
Texaco Exploration and Production Inc. Modification to tank battery

500 and 750 bbl fixed roof storage tanks
1/27/92

(A/C nos. 4271310B, 4271317B, and 4271319B)

A350-549-92

District Contact:
Tom Goff
San Joaquin Valley Unified APCD
(805) 862-5200  
Hy-Bon H-12 vapor compressor from four storage tanks routed to existing TEOR vapor incineration system

95% control efficiency
       
Wickland Oil Company MTBE tank farm

Thirteen fixed roof storage tanks with
10,000 bbl/hr throughput
7/19/91

(A/C no. 6719)

A350-538-92

District Contact:
Greg Solomon
Bay Area AQMD
(415) 749-4715  
John Zink carbon adsorption/absorption system

1 lbm/1000 bbl
(Expected control efficiency of greater than 99%)
       
Union Oil Co.
(Lompoc Dehydration Facility)

160-barrel crude oil storage tanks
6/20/86
(

(A/C no. 6708)

A350-335-89

District Contact:
Bill Master
Santa Barbara Co. APCD
(805) 961-8800  
Hard-piped, closed vapor control system

100% control of non-fugitive emissions
       
Gaviota Terminal Co.

Six crude oil storage tanks with 100,000 bbl/day throughput; storage tanks range in size from 35,000 to 235,000 bbl
5/13/87

(A/C no. 6408)

A350-322-89

District Contact:
Sanjib Mukherji
Santa Barbara Co. APCD
(805) 961-8800  
Double-seal internal floating roofs; venting of vapors to hard-piped, closed facility vapor collection system and incinerator

95% control
(NSPS requirement)
       
Exxon Co. USA

Crude oil and natural gas liquids storage tanks
11/19/87

(A/C no. 5651)

A350-314-89

District Contact:
Sanjib Mukherji
Santa Barbara Co. APCD
(805) 961-8800  
Hard-piped vapor control tied into vapor recovery and control system of oil treatment plant (see record A350-313-89)

99.8% control of non-fugitive emissions (100% collection efficiency, except for fugitive emissions)
       
Dow Chemical

30,000 gal fixed-roof, above-ground storage tank
11/12/86

(App. no. 147045)

A360-175-87

District Contact:
Belinda Wan
South Coast AQMD
(909) 396-2532
bwan@aqmd.gov
Spray scrubber and carbon adsorber

No limit
(Estimated control level of 99.3%)
       
Oil Process Co.

265 gpm process vessels for oil-water separation and storage tanks
11/8/86

(App. no. 129939)

A350-174-87

District Contact:
Belinda Wan
South Coast AQMD
(909) 396-2532
bwan@aqmd.gov
Incinerator and caustic scrubber

No limit
(Estimated control level of 90%)
       
Chevron-Gaviota

Crude and natural gas liquids storage tanks
2/6/86

(A/C no. 5704)

A350-128-86

District Contact:
Bill Master
Santa Barbara Co. APCD
(805) 961-8800  
Hard-piped, closed vapor control systems

100% control
       
Sun Exploration and Production

Tank battery
5/8/86

(A/C no. 4014503)

A350-124-86

District Contact:
Tom Goff
Kern Co. APCD
(now the San Joaquin Valley Unified APCD)
(805) 862-5200  
Vapor control system with incineration

0.17 lbm/hr
99% control
       
Elk Hills N.P.R. #1

Drain tank
4/26/86

(A/C no. 4091177)

A350-123-86

District Contact:
Tom Goff
Kern Co. APCD
(now the San Joaquin Valley Unified APCD)
(805) 862-5200  
No control

0.22 lbm/day
       
Elk Hills Naval Reserve #1

Crude oil storage tank
4/26/86

(A/C no. 4091176)

A350-121-86

District Contact:
Tom Goff
Kern Co. APCD
(now the San Joaquin Valley Unified APCD)
(805) 862-5200  
Vapor collection vented to natural gas pipeline

99.7% control
       
HOPCO

Crude oil storage tank
12/4/84

(A/C # 4099105 to 4099124)

A350-60-84

District Contact:
Tom Paxon
San Joaquin Valley Unified APCD
(former Kern County APCD)
(805) 861-3682  
Vapor collection and incineration

99-6% control efficiency
       
Cheveron USA, Inc. (Add 2 Tanks to Battery)

Two 5000 and 2000 bbl cone roof tanks
11/21/84

(A/C # 4008407B)

A350-058-84

District Contact:
Tom Paxon
San Joaquin Valley Unified APCD
(former Kern County APCD)
(805) 861-3682  
Engersol Rand vapor recovery to gas plant intake by a compressor

15.1 lbm/day
       
Mineral Spirits Internal Floating Roof Tank

3,300 bbl interal floating roof tank
6/18/84

(A/C # 2018063)

A350-044-84

District Contact:
Tom Paxon
San Joaquin Valley Unified APCD
(former Kern County APCD)
(805) 861-3682  
Altech Industries Co. single-seal internal floating roof with no-gap seal retained by 10 pound force or greater

98% control efficiency
       
Tankage change of service and vapor control system modification

Rerun charge and heavy naptha storage tanks
1/4/84

(A/C # 218009C, 059-61)

A350-032-84

District Contact:
Tom Paxson
San Joaquin Valley Unfied APCD
(former Kern County APCD)
(805) 861-3682  
Incineration of vapors in existing refinery fuel gas system

95% control efficiency
       
CAPCOA BACT Clearinghouse Source Category - 167 Storage Tanks

BEST AVAILABLE CONTROL TECHNOLOGY DETERMINATION DATA SUBMITTED TO THE
CALIFORNIA AIR POLLUTION CONTROL OFFICERS ASSOCIATION BACT CLEARINGHOUSE

Equipment or Process: Sulfur Recovery Plant Revision: 3.0
Equipment Rating: All Date 07/18/00
Project Name & Description A/C Issue Date & ARB File No. BACT AND CORRESPONDING EMISSION CONTROL LEVELS
VOC/HC NOx SOx CO PM/PM10
Pacific Offshore Pipeline Co.

Sulfur recovery unit at oil-field natural gas processing plant with 60 MMscfd gas output to sulfur recovery unit at 2.67 hydrogen sulfide
2/4/97

(A/C no. 9047)

A350-745-97

District Contact:
Steve Sterner
Santa Barbara Co. APCD
(805) 961-8886
sterners@sbcapcd.org
    Three-stage conversion process of hydrogen sulfide in acid gas from a sulfinol amine system to elemental sulfur

99.9% H2S removal by mass across the sulfur recovery unit
100 ppmv residual H2S Stretford tail gas prior to incineration
   
Texaco Refining and Marketing - Bakersfield

Three-stage Claus sulfur recovery unit with a capacity of
90 long tons/day liquid sulfur at a refinery
4/18/91

(A/C no. 200T245)

A350-477-91

District Contact:
Tom Goff
Kern Co. APCD
(now the San Joaquin Valley Unified APCD)
(805) 862-5200  
    Amine-based, tail-gas treating unit

10 ppmvd
(Expected control efficiency of 99.9%)
   
Chevron-Gaviota

Four 7.5 MMscf/day sulfur recovery units
2/6/86

(A/C no. 5704)

A350-126-86

District Contact:
Bill Master
Santa Barbara Co. APCD
(805) 961-8800  
Pipeline quality gas in tail-gas incinerator; proper burner operation

3.64 lbm/hr total
Pipeline quality gas in tail-gas incinerator; proper burner operation

200 ppmvd at 3% oxygen
15.2 lbm/hr total
Recycle selection process combined with tail-gas incinerator and caustic scrubber

90 ppmvd at 3% oxygen
99.9% control
Pipeline quality gas in tail-gas incinerator; proper burner operation

6.16 lbm/hr total
Use of pipeline quality gas in tail-gas incinerator; caustic scrubber with mist eliminator

3.66 lbm/hr total
80% control
CAPCOA BACT Clearinghouse Source Category - 169 Sulfur Recovery Plant

BEST AVAILABLE CONTROL TECHNOLOGY DETERMINATION DATA SUBMITTED TO THE
CALIFORNIA AIR POLLUTION CONTROL OFFICERS ASSOCIATION BACT CLEARINGHOUSE

Equipment or Process: Tire Buffers Revision: 3.0
Equipment Rating: All Date 07/18/00
Project Name & Description A/C Issue Date & ARB File No. BACT AND CORRESPONDING EMISSION CONTROL LEVELS
VOC/HC NOx SOx CO PM/PM10
Scoettler Tires

Tire buffing (tread removal) station including a 42.2 hp SIO model Ra2EC single-head tire with a water spray at the rasp head. Unit processes 600 tires/day.
12/27/99

(A/C No.: C-3618-1-0)

A410-952-00

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909
george.heinen@valleyair.org
        Water spray at the rasp. Vacuum hood ducted to BAZ Recycling, Inc. high-efficiency cyclone dust collector

0.015 lb PM10/tire with a processing rate of 600 tires/day
Cumming-Henderson, Inc.

Tire retreading operation utilizing adhesives for tire repair and retreading
7/16/96

(A/C no. N-3648-2-0)

A410-728-96

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
Use of the adhesives with a VOC content of 5.2 lbm/gal (less water and exempt compounds)

5.2 lbm/day
       
Five Bros., Inc.

Bandag Model 365 tire buffer
3/20/89

(App. no. 182589)

A410-395-90

District Contact:
Rich Hawrylew
South Coast AQMD
(909) 396-2657
rhawrylew@aqmd.gov
        Cyclone

No limit
(Estimated emissions of 1.25 lbm/day)
Five Bros., Inc.

Bandag Model
No. 81-10 tire buffer
11/1/89

(App. nos. 210888 and 210889)

A410-356-90

District Contact:
Rich Hawrylew
South Coast AQMD
(909) 396-2657
rhawrylew@aqmd.gov
        B&J Cyclone Model 36-30-100

No limit
Five Bros. Tire

30 hp tire buffer
Permit to Operate Issued 3/5/88

(App. no. 153194)

A410-240-87

District Contact:
Sean Cullins
South Coast AQMD
(909) 396-2655
scullins@aqmd.gov
        Water spray at rasp and cyclone

No limit
(Estimated emission control of 99.3%)
CAPCOA BACT Clearinghouse Source Category - 174 Tire Buffers

BEST AVAILABLE CONTROL TECHNOLOGY DETERMINATION DATA SUBMITTED TO THE
CALIFORNIA AIR POLLUTION CONTROL OFFICERS ASSOCIATION BACT CLEARINGHOUSE

Equipment or Process: Water Treating - Oil/Water Separator Revision: 3.0
Equipment Rating: All Date 07/18/00
Project Name & Description A/C Issue Date & ARB File No. BACT AND CORRESPONDING EMISSION CONTROL LEVELS
VOC/HC NOx SOx CO PM/PM10
U.S. Borax, Inc.

Borate tailing ponds used for future reclaiming of borate minerals. Ponds have been a source of fugitive dust emission depending on wind conditions
9/28/95

(A/C no. 1004207A)

A390-670-95

District Contact:
William Lund
Kern County APCD
(805) 861-2593  
        DLR-MS-40 acrylic copolymer and reclaimation ponds previously dry

68.5 lbm/day
General Cable Corp.

Data and communication cable insulation printing operation using Medek and Schoener bandmarker
8/8/95

(A/C no. C-563-21-0)

A340-669-95

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
Low VOC ink

1.68 lbm/gal of ink
       
Superior Ag Resources

Jet-Pro dryers with Maxon "NP/RG airflow burners and pelletizing equipment. Dryers have eleven
7.8 MMBtu/hr burners.
7/12/95

(A/C no. S-335-5-2)

A370-668-95

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
  Natural-gas firing

0.075 lbm/MMBtu
    High-moisture feed, Jet-Pro 1D-2D high efficiency cyclones

0.006 gr/dscf
Liquid Waste Management, Inc.

Truck dump decanting/mixing/
settling/equalization (DMSE) pits preceding a new covered wastewater separator limited to 100,000 gal wastewater/day throughput
3/13/95

(A/C no. S-730-16-0)

A430-635-95

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
None

No limit
(Emissions approximately
49 lbm/day)
       
ARCO Oil and Gas Co.

640 bbl organic liquid storage tank receiving crude oil and steam injection as part of tertiary oil recovery operation. Tank has 1035 bbl/day maximum throughput.
11/5/91

(A/C no. 4007262A)

A350-493-91

District Contact:
Tom Goff
San Joaquin Valley Unified APCD
(805) 862-5200  
Vapor collection system vented to natural gas pipeline

No limit
(Expected fugitive emissions of 0.02 lbm/day)
       
CAPCOA BACT Clearinghouse Source Category - 177 Water Treating - Oil/Water Separator

BEST AVAILABLE CONTROL TECHNOLOGY DETERMINATION DATA SUBMITTED TO THE
CALIFORNIA AIR POLLUTION CONTROL OFFICERS ASSOCIATION BACT CLEARINGHOUSE

Equipment or Process: Water Treating - Sour Water Stripping Revision: 3.0
Equipment Rating: All Date 07/18/00
Project Name & Description A/C Issue Date & ARB File No. BACT AND CORRESPONDING EMISSION CONTROL LEVELS
VOC/HC NOx SOx CO PM/PM10
Exxon Company, USA - Las Flores Canyon (Santa Ynez Unit)

30,900 barrels, fixed cone roof wastewater equalization tank
1/27/99

(A/C no. 5651-17)

A350-875-99

District Contact:
Michael Goldman
Santa Barbara County APCD
(805) 961-8821
goldmanm@sbcapcd.org
Two carbon canister at the outlet of the hydrogen sulfide scrubber(in parallel)

75% removal efficiency

Voluntary information on controls. BACT not required.
  H2S: Packed-bed design, Venturi scrubber with a 4% caustic solution and two carbon canister polishing units at the outlet of the scrubber (in parallel) to further reduce hydrogen sulfide levels

13 ppmv
99.9% removal efficiency
   
CAPCOA BACT Clearinghouse Source Category - 178 Water Treating - Sour Water Stripping

BEST AVAILABLE CONTROL TECHNOLOGY DETERMINATION DATA SUBMITTED TO THE
CALIFORNIA AIR POLLUTION CONTROL OFFICERS ASSOCIATION BACT CLEARINGHOUSE

Equipment or Process: Miscellaneous Revision: 3.0
Equipment Rating: All Date 07/18/00
Project Name & Description A/C Issue Date & ARB File No. BACT AND CORRESPONDING EMISSION CONTROL LEVELS
VOC/HC NOx SOx CO PM/PM10
College of the Desert

5.05 MMBtu/hr Trane model ABDA 0440 direct-fired absorption chiller producing 464 tons cooling use to provide cooling to buildings during peak demand periods. Unit is fired on natural gas.
P/O Date: 3/16/00

(P/O F25619)

A310-984-00

District Contact:
Maria Vibal
South Coast AQMD
(909) 396-2422
mvibal@aqmd.gov
  Weishaupt low-NOx burner and flue gas recirculation

20 ppmv @ 3% O2
  No control

50 ppmv @ 3% O2
 
La Paloma Generating Co. LLC

Two cooling towers to provide heat rejection for the GTEs and steam turbines. Each cooling tower will consist of 10 cells and have a water flow rate of 104,000 gals/min and 155,380 acf/sec
n.d.

(A/C # S-3412-5-0 and 6-0)

A340-975-00

District Contact:
Leonard Scandura
San Joaquin Valley Unified APCD
(661) 326-6900  
        Dirft eliminators with a drift rate of 0.0006%

0.0006% dift rate
Federal Bureau of Prisons

7.6 MMBtu/hr natural gas-fired gas absorption chillers (GAC) for air conditioning.
11/12/99

(A/C No.: S-2718-7-0)

A310-958-00

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909
george.heinen@valleyair.org
  Coen Micro-NOx HTE-10 low-NOx burner

20 ppmv @ 3% O2
     
Scoettler Tires

Tire retarding process line including a retreading station and a 19.3 hp Cure Tech CTS-3000 curing chamber (autoclave). The station includes a 38.4 hp extruder, a 1.6 hp accumulator, and a 5.4 hp ultrasonic tread applicator
12/27/99

(A/C No.: C-3618-5)

A410-953-00

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909
george.heinen@valleyair.org
Use of Michelin retread technology for retreading tires

0.0133 lb VOC/tire
600 tires/day
       
Aramark Uniform Cleaners

Facility processes solven-laden towels and uniforms. Items are counted on a table served by uncontrolled exhaust hood and placed into industrial washers and dryers (Challenger CPG4-3S3L burners, 2.75 MMBtu/hr).
10/4/99

(A/C No.: C-45-11-0)

A340-951-00

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909
george.heinen@valleyair.org
  2.75 MMBtu/hr natural gas-fired burner

49.3 ppmv
     
Action Purchasing, Inc.

Nordmeccanica model Accoppiatrice, Super Simplex Combi laminator with two Encercon model LM3731-01 Corona Treaters, each rated at 7.5 kW
7/29/99

(A/C No.: 356206)

A430-949-00

District Contact:
Asha G. Rawal
South Coast AQMD
(909) 396-2506
arawal@aqmd.gov
Pillar Technologies catalyst bed and compliance with Rule 1168 limit

22 lbs/day facility limit
       
Rainbow Coating, Inc.

3.7 MMBtu/hr conveyorized powder coating curing oven
n.d.

(A/C No.: 360365)

A340-948-00

District Contact:
Asha G. Rawal
South Coast AQMD
(909) 396-2506
arawal@aqmd.gov
Use of Regulation XI compliant materials

667 lbs/month VOC facility wide
Maxon model Cyclomax low-NOx burner

30 ppmvd @ 3% O2
     
The BOC Group, Inc.

Toromont Process System use for carbon dioxide recovery with a total flow rate of 9300 scfm
11/17/99

(A/C No.: 358093)

A430-943-00

District Contact
Pablo Pua
South Coast AQMD
(909) 396-2597
ppua@aqmd.gov
ADWEST Technologies, Inc. RETOX RTO95 thermal oxidizer

98% overall control efficiency of TOC
    ADWEST Technologies, Inc. RETOX RTO95 thermal oxidizer

100 ppm
10 ppm
 
DA/PRO Rubber Inc.

Lufkin rubber roll mill and organic mixing mill use to prepare rubber dough. No organic solvents shall be added to this equipment. Maximum operating temp. of the roll mill shall not exceed 200 F.
7/30/99

(A/C No.: 356068)

A430-942-00

District Contact:
Belinda C. Wan
South Coast AQMD
(909) 396-2532
bwan@aqmd.gov
        Torit, model DFT3-6 pulse jet cleaning baghouse with a filter area of 1524 sq. ft.

No limit
Morton International - Electronic Materials

PSSM conveyorized SHD Developer use to develop imigable films (photoresist) for the printed circuit industry. Materials handled include a solutions of gamabutyrolactone or propylene carbonate.
8/18/99

(A/C No.: 352219)

A430-941-00

District Contact:
Belinda C. Wan
South Coast AQMD
(909) 396-2532
bwan@aqmd.gov
Solvent vapor pressure not to exceed 5 mm Hg at 68 degrees F. Equipment solvent losses not to exceed 2 gallons/month.

20 lbs/month
       
Gordon Laboratories

2500 gallon hair spray mixing tank with a 5 hp agitator limited to processing 1 batch per day. Materials processed include ethyl alcohol, surfactants, fragrances, and other liquids. Limit of 1.86 lb ethyl alcohol/batch.
10/29/99

(A/C No.: 353829)

A360-940-00

District Contact:
Belinda C. Wan
South Coast AQMD
(909) 396-2532
bwan@aqmd.gov
Carbon Activated Corporation carbon adsorber containing 200 pounds of activated carbon

No limit
       
Medtronic Avalon Laboratories, Inc.

Polyurethane Tube (Bio-Cannula) Manufacturing System. To produce polyurethane tubes called bio-cannulas which are used as medical devices
10/14/99

(A/C No.: 356145)

A360-939-00

District Contact:
Belinda C. Wan
South Coast AQMD
(909) 396-2532
bwan@aqmd.gov
Two parallel systems consisting of two pre-filtered American Filtration Systems, Inc., model Boxsorber, non-regenerative carbon adsorbers in series. Each containing 4000 lbs of activated carbon

No limit
(95% control efficiency warrentied)
       
Dart Container Corporation of California

Gloucester 1000 lbs/hr direct injection polystyrene foam extrusion
9/10/99

(A/C No.: 347406)

A360-935-00

District Contact:
Mark Liu
South Coast AQMD
(909) 396-2538
mliu@aqmd.gov
Smith Environmental natural gas-fired 8 MMBtu/hr regenerative thermal oxidizer with two ceramic beds

3281 lbs VOC/day facility limit; 98% destruction efficiency
       
Van Waters & Rogers

Three container filling stations with 55,000 gal/day total output for packaging organic liquids, such as styrene, mineral spirits, perchloroethylene, etc., or mixtures of organic liquids and powder into containers.
9/9/99

(A/C No.: 353759)

A360-918-00

District Contact:
Belinda C. Wan
South Coast AQMD
(909) 396-2532
bwan@aqmd.gov
John Zink model ZCS-1-4-20X-3/10 direct-flame thermal oxidizer with two 3.6 MMBtu/hr natural gas-fired burners. One burner is for the passive source and one is for the blower-assisted sources

4 tons/yr VOC emissions facility wide (95% control)
       
Cheron Products Co.

653 MMBtu/hr Born Heaters reformer furnace located at the Steam Naphtha Reformer Plant and is used for hydrogen production
3/24/99

(RECLAIM 341340)

A330-907-99

District Contact:
Pablo L. Pua
South Coast AQMD
(909) 396-2597
ppua@aqmd.gov
  Haldor Topsoe selective catalytic reduction system

5 ppmvd @ 3% O2, 3-hour average
  No control

25 ppmvd @ 3% O2, 3-hour average
 
PG Imtech of California

Batch Vapor Degreasing Operation; Serec Corporation Airless Vapor Degreaser, model 484836 evacuated cleaning chamber use to clean castings, stampings, and deep draw metal springs with a 300 lb load capacity.
3/3/96

(A/C No. 300265)

A340-904-99

District Contact:
Jakson Yoong
South Coast AQMD
(909) 396-3125
jyoong@aqmd.gov
Serec airless vapor degreaser with an evacuated cleaning chamber. Solvents are separated by refrigerated condensation, distillation and gilering processes. Any remaing vapor is routed to a carbon bed for adsorption

3 gal/mth
40 lb/mth
       
Vickers Inc., Sterers Division

Batch Vapor Degreasing Operation; Baron Blakeslee airless vapor degreaser model NZE-2430H evacuated cleaning chamber with a 50 lbs load capcity.
5/15/95

(A/C No. 299578)

A340-903-99

District Contact:
Bill Milner
South Coast AQMD
(909) 396-2553
bmilner@aqmd.gov
Baron Blakeslee airless vapor degreaser with an evacuated cleaning chamber. Solvents are separated by refirgerated condensation , distillation and filtering processes. Any Vapor is routed to a carbon bed for adsorption

3 gal/mnth
40 lb/mnth
       
BF Goodrich Areospace

Batch Vapor Degreasing Operation; Serec Corporation Airless Vapor Degreaser, model 60120 evacuated cleaning chamber with a 30 lbs load capacity.
11/2/94

(A/C No. 296689)

A340-902-99

District Contact:
Bill Milner
South Coast AQMD
(909) 396-2553
bmilner@aqmd.gov
Serec airless vapor degreaser with an evacuated cleaning chamber. Solvents are separated by refrigerated condensation, distillation and gilering processes. Any remaing vapor is routed to a carbon bed for adsorption

180 lbs PERC/month
       
Digital Printing System, Inc.

Ticket Printing System consisting of: 1)Flexographic press, Mark Andy, Web-Fed, model 2100, 6-color, 7"-width, 5hp; 2) Drying Oven, Mark Andy, model 82-852, 36 KVA electrically heated, w/ a 2 hp exhaust fan;
6/7/94

(Application no. 293233)

A430-897-99

District Contact:
Knut Beruldsen
South Coast AQMD
(909) 396-3136
kberuldsen@aqmd.gov
Ultra-violet drying system

7 lb/day for system
       
Coyle Reproductions, Inc.

Screen Press, Custom manual, one color sheeted with an ultra-violet dryer.
8/3/94

(Application no. 289558)

A430-896-99

District Contact:
Knut Beruldsen
South Coast AQMD
(909) 396-3136
kberuldsen@aqmd.gov
Ultra-violet dryer

5.3 lb/day
       
Clinton Inc., West Coast Labels DBA

Flexographic Printing Press no. 1, Aqua Flex, model 1000 DBX, 10" width, seven color, 15 hp total with a 7.2 KW ultra-violet oven.
n.d.

(Application no. 290715)

A430-895-99

District Contact:
Knut Beruldsen
South Coast AQMD
(909) 396-3136
kberuldsen@aqmd.gov
Ultra-violet oven

No Limit
       
Best Label Co. Inc.

Printing and drying system no. 14 including: 1) Unwind station: 2) Rotary letterpress, gallus, model no. R-160-B, eight color units, with one 16 hp main drive; and 3) 7 curing units, ultraviolet type, each with one 4 KW lamp
n.d.

(Application no. 287260)

A430-892-99

District Contact:
Knut Beruldsen
South Coast AQMD
(909) 396-3136
kberuldsen@aqmd.gov
All inks and varnishes must have zero or less than one percent VOC content, and will be UV-cured.

7.9 lb/hr
40 lb/day
       
Container Supply Co. Inc.

Kase Equipment model KSP-6612, six color pail printer with flame treatment unit and a 0.9 KW ultraviolet in curing system.
11/9/94

(Application no. 297973)

A430-890-99

District Contact:
Knut Beruldsen
South Coast AQMD
(909) 396-3136
kberuldsen@aqmd.gov
Ultraviolet ink curing system

6 lb VOC/day
       
Edwards Air Force Base

Disposal of waste propellant and propellant contaminated materials.
1/29/99

(A/C No. 0134112)

A320-888-99

District Contact
Doug Ray:
Kern County APCD
(805) 862-5250
kcapcd@co.kern.ca.us
        Chemical hydrolysis operation using a sodium hydroxide solution, a shredder, and a digester tank.

No limit
H&H Heat Treating

7 MMBtu/hr natural gas-fired Abar Ispen model HH 170, serial no. 60416, heat treating furnace with LPG backup fuel.
9/29/98

(A/C no. 344733)

A310-873-99

District Contact:
Hemang Desai
South Coast AQMD
(909) 396-2596
hdesai@aqmd.gov
  Eleven low NOx burners. Mfgr: North American models 4442-3 (five) and 4442-5 (six)

No limit
     
Niklor Chemical Co., Inc.

Chloropicrin, methyl bromide and 1,3 - dichloropropene packaging operation; Chloropicrin railcar loading
12/14/98

(A/C no. 6001008)

A360-871-98

District Contact:
Doug Ray
Kern County APCD
(805) 862-5250
kcapcd@co.kern.ca.us
Carbon absorber

99% control
       
Niklor Chemical Co., Inc.

Chloropicrin, methyl bromide and 1,3 - dichloropropene packaging operation; Cylinder and bulk container fill stations at gas cylinder filling operation.
12/14/98

(A/C no. 6001007)

A360-870-98

District Contact:
Doug Ray
Kern County APCD
(805) 862-5250
kcapcd@co.kern.ca.us
Carbon absorber or compressor/chiller depending on what cylinders are being refilled

80% control for compressor/chiller
99% control for carbon absorber
       
Niklor Chemical Co., Inc.

Cylinder vent station at gas cylinder filling operation for chloropricin, methyl bromide and 1,3 dichloropropene
12/14/98

(A/C no. 6001005)

A360-869-98

District Contact:
Doug Ray
Kern County APCD
(805) 862-5250
kcapcd@co.kern.ca.us
Compressor/chiller
80% control
       
Niklor Chemical Co., Inc.

Receiving and storage for methyl bromide and 1,3 - dichloropropene
12/14/98

(A/C no. 6001004)

A360-868-98

District Contact:
Doug Ray
Kern County APCD
(805) 862-5250
kcapcd@co.kern.ca.us
Vapor collection system vented to compressor/chiller

80% control
       
Niklor Chemical Co., Inc.

Liquid chlorine railcar unloading
12/14/98

(A/C no. 6001001)

A360-867-98

District Contact:
Doug Ray
Kern County APCD
(805) 862-5250
kcapcd@co.kern.ca.us
Nitrogen purge system. Chlorine unloading line will be purge with nitrogen for 10 minutes at the end of each work day and prior to disconnecting the railcar

No Limit

Chlorine pollutant with Toxic BACT regulatory requirement
       
Niklor Chemical Co., Inc.

Chloropicrin manufacturing equipment including raw material tanks, static mixer, settling, collection, drying and storage tanks to vapor collection system.
12/14/98

(A/C no. 6001003)

A360-866-98

District Contact:
Doug Ray
Kern County APCD
(805) 862-5250
kcapcd@co.kern.ca.us
Dual bed carbon adsorber with two 600 pound carbon beds and steam regeneration cycle.

50 ppmvd
99% average control efficiency
       
Fruend Baking Co.

Bakery oven, baker environmental, model 40A, natural gas/propane fired, with a platinum based cataylst with a rated input of 7,000,000 Btu/hr
7/16/97

(A/C no. 328570)

A370-864-98

District Contact:
Hemang Desai
South Coast AQMD
(909) 396-2596
hdesai@aqmd.gov
CSM Environmental model 40A catalytic oxidizer with platinum based catalyst and natural gas/propane firing

No limit
(Expected emission concentration of 55.8 ppmvd and 95.4 destruction efficiency)
       
Applied Magetics Corperation - Robin Hill Road Facility

Electromagnetic device manufacturer using photo-resist resin developers and applicators, and solvent workstations
11/13/98

(A/C no. 9890)

A430-863-98

District Contact:
Michael Goldman
Santa Barbara County APCD
(805) 961-8821
goldmanm@sbcapcd.org
Regenerative thermal oxidizer (RTO); Mfgr: Smith Engineering Company; model: Packaged Thermal Oxidizer (PTO); Rating: 15,000 scfm

98% mass destruction rate efficiency or 10 ppmv ROC (as propane)
       
FlowMatrix Corp. - Carpinteria

Solvent devolatization hoods (dipping room) and curing oven
11/10/98

(A/C no. 9985)

A340-861-98

District Contact:
Michael Goldman
Santa Barbara County APCD
(805) 961-8821
goldmanm@sbcapcd.org
Recuperative thermal oxidizer (mfgr: GeoEnergy International, model: GeoTherm 1600) Rating: 1,800 scfm

99% mass destruction rate efficiency, or 10 ppmv ROC (as Propane)
       
Maple Leaf Bakery

Four bakery ovens with a total of nine process stacks: 3.07 MMBtu/hr Baker Perkins Oven, 1.8 MMBtu/hr and 2.5 MMBtu/hr Mekatherm Ovens, and 5.1 MMBtu/hr Universal Oven.
10/6/98

(A/C no. 0473-170)

A370-858-98

District Contact:
Kerby Zozula
Ventura County APCD
(805) 645-1421
Kerby@vcapcd.org
Anguil model 75 TCO catalytic oxidizer, 7500 scfm, 3.36 MMBtu/hr. This single catalytic oxidizer, emissions from all four ovens (multiple stacks)

92% destruction efficiency rate
600oF
       
Shell Martinez Refining Company

Refinery fuel gas system for various combustion sources (furnaces, boilers, CO boilers)
7/28/98

(A/C no. 18185)

A350-856-98

District Contact:
Greg Stone
Bay Area AQMD
(415) 749-4745
gstone@baaqmd.gov
    H2S and total reduced sulfur (TRS) in refinery fuel gas system reduced by Diethanolamine (DEA) absorder, Claus Sulfur Plant, and SCOT unit.

24 hr average H2S content limit of 50 ppm
Annual average TRS limit of 70 ppm
   
The Rod McLellan Company

Plotting soil mixing and bagging operation with 245 ton/day thoughput limit
2/2/98

(A/C no. N-3927-2-0)

A370-843-98

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
        Water sprinkler system maintaining minimum moisture content of 20%

0.5 lbm/ton material processed
5% opacity
City of Modesto, Compost Facility

Transportable woodwaste grinding operation consisting of a Diamond Z model 1260 PWG tub grinder driven by a 750 hp diesel-fired IC engine with throughput limited to 500 tons/day
4/3/98

(A/C no. N-3993-1-0)
A430-839

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
        A water sprinkler system or maintaining adequate moisture content of the process material to prevent visible emissions in excess of 5% opacity

0.05 lbm/ton
City of Modesto, Compost Facility

Composted materials screening operation consisting of a Power Screen Model 620 portable trommel screen driven with a 97 hp diesel-fired IC engine.
4/3/98

(A/C no. N-3993-2-0)

A430-838-98

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
        A water sprinkler system or maintaining adequate moisture content of the process material to prevent visible emissions in excess of 5% opacity

0.04 lbm/ton material processed
Sterling West, Inc.

Paper coatings line #1: Two 3 hp Michelman MRC-1000 in-line rod coaters and two 10 MMBtu/hr natural gas-fired dryers, each equipped with two 5 MMBtu/hr Maxon Cyclomax 5.0 low-NOx burners
1/20/98

(A/C no. C-3618-1-0)

A340-837-98

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
Low-VOC, water-based coatings, with a maximum VOC content of 0.3 lb/gal for colored and functional coatings and 0.74 lb/gal for specialty coatings (less water and exempt componds, repectively)

98.0 lbm/day
       
Pelco

Converyorized 5 stage washer with 3.8 MMBtu/hr and 2.5 MMBtu/hr natural gas-fired Maxon Series "67" Tube-O-Flame burners
1/27/98

(A/C no. C-922-6-0)

A340-836-98

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
  No control

15.4 lbm/day
     
Delta Plastics

Spray application of contact adhesives for countertop manufacturing
11/24/97

(A/C no. N-2393-1-2)

A340-827-98

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
Using adhesives with a VOC content of 540 grams/liter or less(less water and exempt compounds)

15 lbm/day
       
Darling & Durst

Diesel switchloading operation (diesel/gasoline switch loading at a bulk terminal)
10/30/97

(A/C no. C-403-6-0)

A350-826-98

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
Using CARB tested and certified 95% effective Vapor Recovery System

95% control
       
Custom Marble & Onyx

Polyester resin operation with casting molds changing with every new job.
4/4/97

(A/C no. N-3715-2-1)

A430-813-97

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
Low-VOC resins with monomer wt. content <= 34%; and low-VOC clear gel coats with a monomer wt. content <= 47%

28.4 lbm/day
       
Enviroplex, Inc.

Metal frames and exterior coating of wooden wall panels for modular building manufacturing
3/20/97

(A/C no. N-3780-2-0)

A340-812-97

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
Primers with VOC content of 1.8 lbm/gal for metal frames coating and pigmented topcoats with a VOC content of 1.1 lbm/gal for exterior coatings of wooden wall panels.

18.8 lbm/day
      Use of an HVLP or District Rule 4603/4606 compliant coating application methods

29.4 lbm/day
Florestone Products Co.

Manufacturig of plumbing fixtures: 45 bhp shower stalls chop spray process # 2, including 20 molds, 6 binks air spray booths and 2 wash air dring tunnels. Resin use limited to 600 gal/day and 79309 gal/yr
7/15/96

(A/C no. C-495-5-2)

A410-810-97

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
Use of vapor supressed low VOC resins limited to 35%, use of air assisted airless spray and use of non VOC clean-up solvents

80 lbm/day and 3.82 tons/yr
       
Florestone Products Co.

Manufacturing of plumbing fixtures: 45 bhp shower stall chop spray process # 1 including 20 molds, 6 air spray booths, and 2 wash air drying tunnels. Resin use limited to 600 gal/day and 79309 gal/yr.
7/15/96

(A/C no. C-495-4-2)

A410-809-97

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
Use of vapor supressed low VOC resins limited to 35%, use of air assisted airless spray and use of non VOC clean-up solvents

80 lbm/day and 3.82 tons/yr
       
Florestone Products Co.

Manufacturing of plumbing fixtures: 7.5 bhp shower stall gel spray process # 2, including 20 molds and associated equipment Resin use limited to 100 gal/day and 22192 gal/yr. VOC content of resin shall not exceed 35% by wt.
7/15/96

(A/C no. C-495-3-2)

A410-808-97

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
Use of low VOC resins less then 39%, use of air assisted airless spray and use of none VOC clean-up solvents

80 lbm/day and 8.93 tons/yr
       
Florestone Products Co.

Manufacturing of plumbing fixtures: 7.5 bhp shower stall gel spray process #1 including 20 molds and associated equipment. Resin use limited to 100 gal/day and 22192 tons/yr. VOC content of resin shall not exceed 35% by wt.
7/15/96

(A/C no. C-495-2-2)

A410-807-97

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
Use of low VOC resins less then 39%, use of air assisted airless spray and use of none VOC clean-up solvents

80 lbm/day and 8.93 tons/yr
       
Florestone Products Co.

Maufacturing of plumbing fixtures: 235 bhp compression molding process with 7 presses and 5 roller lines. Resins use limited to 2,900 gal/day
7/15/96

(A/C no. C-495-1-2)

A410-806-97

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
Closed compression molding and use of non VOC clean-up solvents. Filler and resin mixed in closed container. Resin monomer content limited to 28% by weight

22 lbm/day and 2.11 tons/yr
       
J.G. Boswell

825 bhp vegetable and cotton seed decortication with 3 decorticator/sepertor, hull beaters, a scalper served by 6 1D-3D cyclone dust collector exhausting into a Continental Air Systems model 10-7 Outr-A-Vac rotary drum filter
4/22/97

(A/C no. C-1555-2-2)

A370-804-97

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
        Six 1D-3D cyclone dust collectors exhausting into a Continental Air Systems model 10-7 Outr-A-Vac rotary filter

0.0074 lbm/ton
Carpenter Co.

Adhesive application process
5/16/97

(A/C no. N-180-21-0)

A340-803-97

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
Low-VOC adhesives

8.4 lbm/day
       
Quality Assured Packing, Inc.

3.2 MMBtu/hr natural gas-fired tomato roaster
6/12/97

(A/C no. N-657-6-0)

A370-801-97

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
  Operation of burner within manufacturer's specifications to minimize NOx emissions

0.1 lbm/MMBtu
     
Andrea Zee Corp. Dba Marble Palace

Polyester resin operation with casting molds changing with every new job
5/21/97

(A/C no. N-3791-1-0 & 2-0)

A430-800-97

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
        Spray booth with exhaust filters and air filters assisted airless spray equipment

9.7 lbm/day combined limit
Custom Marble and Onyx

Polyester resins operation with casting molds changing with every new job
4/4/97

(A/C no. N-3715-1-1)

A430-799-97

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
Low-VOC resins with a monomer wt. content limit of 34% and low-VOC clear gel coats with a monomer wt. content limit of 47%

16.5
       
Enviroplex, Inc.

Metal frames and exterior coating of wooden wall panels for modular building manufacturing
3/20/97

(A/C no. N-3780-1)

A340-798-97

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
Primers with a VOC content of 1.8 lbm/gal and metal frames coating and pigmented topcoats with a VOC content of 1.1 lbm/gal (less water and exempt compounds) for exterior coating of wooden wall panels.

25 lbm/day
      HVLP or District Rule 4603/4606 compliant coating application methods

29.4 lbm/day
Sigma Circuits

Grace accuspray soldermask system with a capacity of 2000 boards/day
6/30/97

(A/C no. N-211-4-1)

A430-797-97

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
Anguil model 20 catalytic oxidizer

63.2 lbm/day
       
American Gas and Automotive

Gasoline station, 20,000 gal and 12,000 gal tanks, 16 nozzles; processing 6000000 gal/yr
11/19/97

(A/C no. 9824)

A350-795-97

District Contact:
Rebecca Gaffney
Santa Barbara County APCD
(805) 961-8914  
Phase I vapor recovery system (EO # G-70-97-A), Phase II vapor recovery system (EO # G-70-36-AD), tank vent valves

No listed limit
(Estimated 26.63 lbm/day)
       
Applied Vapor Technology, Inc.

2 MMBtu/hr vapor generator firing on VOC contaminated vapors with LPG as auxiliary fuel
7/24/97

(A/C no. S-2986-1-0)

A340-790-97

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
  LPG as auxiliary fuel

0.148 lbm/MMBtu
     
Enviroplex, Inc.

Exterior coating of wooden wall panels on manufactured modular buildings
3/20/97

(A/C no. N-3780-1-0)

A340-789-97

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
HVLP application equipment and water based pigmented topcoats with a VOC content of 1.1 lbm/gal (less water and exempt compounds)

18.8 lbm/day
      HVLP or equivalent application equipment

40.1 lbm/day
Bakersfield City Wood Site

Wood grindling operation - Morbark model 1300 tub grinder with 800 bhp Caterpillar Diesel internal combustion engine
8/6/97

(A/C no. S-2843-3-0)

A330-784-97

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
Positive crankcase ventilation (PCV)

0.16 g/bhp-hr
  Low sulfur diesel fuel (0.05% S by weight)

0.059 g/bhp-hr
No control cost effective

0.83 g/bhp-hr
Positive crankcase ventilation (PCV) and low sulfur diesel fuel (0.05% S by weight

0.21 g/bhp-hr
Holz Rubber Company, Inc.

Brush application of adhesives for rubber to metal parts
9/11/97

(A/C no. N-408-7-1)

A410-782-97

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
VOC content of 17.0 lbm/gal (less water and exempt compounds)

38.0 lbm/day
       
Gold Hills Nut Company

1.2 MMBtu/hr propane-fired Proctor model no. 2500 drier for almond slicing line
11/7/96

(A/C no. N-3290-4-0)

A370-774-97

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
  Propane firing

3.5 lbm/day
(Equivalent to 0.12 lbm/MMBtu)
     
Anderson Clayton Corporation

Cotton seed delinting operation processing up to 100 tons gray seed per day
12/26/96

(A/C no. C-1897-1-3)

A370-773-97

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
        1D-3D cyclone collectors

0.025 to 0.035 gr/scf
Carpenter Company

Non-woven polyester foam line with an 1800 lbm/hr rated capacity
12/6/96

(A/C no. N-180-7-1)

A340-771-97

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
No control
Note: The control devices that were technologically feasible (thermal incineration and carbon adsorption) were not cost effective. There are no control devices for this class and category of source that are achieved in practice
No limit
       
General Cable Corporation

1.0 hp bandmarker used to mark cable insulation limited to 13 gallons/day coating use
11/22/96

(A/C no. C-563-22-0)

A340-770-97

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
Water-based ink with 4.4 lbm VOC/gal less water and exempt compounds

No limit
       
Florestone Products

Manufacturing of plumbing fixtures using 600 gallons resin/day
7/2/96

(A/C no. C-495-4-2 & C-495-5-2)

A410-758-97

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
Vapor-suppressed resins (35% max VOC); air-assisted airless spray; nonVOC cleanup solvent

3.82 tons/yr
       
J.R. Simplot

15 MMBtu/hr natural gas-fired start-up heater at sulfuric acid plant
7/2/96

(A/C no. N-767-58-1)

A360-756-97

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
  Natural-gas fuel

21.6 lbm/day
     
Libbey Owens Ford

0.5 gal/min Ultrasonic Systems, Inc. Utraspray float glass coating system
5/8/96

(A/C no. N-477-45-0)

A390-754-97

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
        Ultraspray float glass coating system as basic equipment

2.8 lbm/day
Pacific Offshore Pipeline Co.

Fugitive hydrocarbon emissions from compressors at an oilfield natural gas processing plant
2/4/97

(A/C no. 9047)

A350-749-97

District Contact:
Steve Sterner
Santa Barbara Co. APCD
(805) 961-8886
sterners@sbcapcd.org
Double mechanical seals with barrier fluid or routing of seal leakage emission points by a closed vent system to a thermal oxidizer; leak detection & repair program

100 ppmv THC w/ EPA Method 21
95% combined capture/destruc. at thermal oxidizer
       
Pacific Offshore Pipeline Co.

Fugitive hydrocarbon emissions from connections at an oilfield natural gas processing plant
2/4/97

(A/C no. 9047)

A350-747-97

District Contact:
Steve Sterner
Santa Barbara Co. APCD
(805) 961-8886
sterners@sbcapcd.org
Flange gaskets of graphitic type or equiv. district approved type, rated at 150 % of process pres. at process temp; static threaded connections

100 ppmv THC using EPA Method 21
       
Lone Star Gas Liquids Processing, Inc.

Swivel joints handling VOCs
5/7/96

(A/C no. S-71-12-1)

A350-741-97

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
Inspection and maintenance consistent with District Rule 4451 for organic liquid loading

2300 ppmv leak rate
       
Basalite Block

1292 ton/hr dry mix concrete/cement bagging machine
6/21/96

(A/C no. N-1051-15-0 & N-1051-16-0)

A390-738-97

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
        Mikro Pul model no. 90-8 baghouse

0.0052 lbm/ton
6.7 lbm/day
Basalite Block

18 MMBtu/hr natural-gas, Carman Industries model no. FBP-1102HT sand drier
6/21/96

(A/C no. N-1051-13-0)

A390-737-97

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
  Natural-gas fuel

0.1 lbm/MMBtu
39.9 lbm/day
    Fabric Filters model 462-12 baghouse

0.0085 lbm/ton
Sequoia Packing Company

Garlic Grading Line
6/10/97

(A/C no. C-1090-2-1)

A370-735-97

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
        Hand-picked garlic with 1D-3D cyclone

0.103 lbm/ton garlic produced
Chevron Gaviota Oil and Gas Plant

General solvent use/wipe cleaning
1/13/97

(A/C no. 9596)

A340-733-97

District Contact:
Mike Goldman
Santa Barbara Co. APCD
(805) 961-8821
goldmanm@sbcapcd.org
Solvent-use minimization; low-vapor pressure solvents; controlled dispenser; containers sealed while not in use; sealed storage of solvent-soaked cloths; & no leaks

10.7 lbm/day
       
Pirreli Armstrong Tire Corporation

899 total HP steel belt manufacuring equipment with two breaktread milling machines, one prefeed mill, one feed mill and one four-roll calendar
9/25/96

(A/C no. C-941-38-0)

A410-731-96

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
None

43.8 lbm/day
       
Parker Hannifin Corp.
Racor Division

Plastisol curing operation, including 2.5 MMBtu/hr fusing oven
8/30/96

(A/C no. N-2089-4-0)

A340-730-96

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
Plastisol with 0.2 % VOC by wt. and natural gas fuel for the fusing oven

3.3 lbm/day
Natural gas used for fuel and low-NOx burner in the fusing oven

0.042 lb/MMBtu
     
Torch Operating Co.
Lompoc Oil and Gas Plant

Sulferox tail-gas unit
12/24/96

(A/C no. 9522)

A350-716-96

District Contact:
Mike Goldman
Santa Barbara Co. APCD
(805) 961-8821
goldmanm@sbcapcd.org
12 MMBtu/hr thermall oxidizer fired with LPG or propane with natural gas backup and with a waste-heat recovery system; Combustion temperature set at 1450 to 1550 F; residence time 0.6 s; tunning once a year

98.5% destr. effic.
10 ppmvd @ 3% O2
       
Integrated Device Technology

Semiconductor fabrication area
9/25/96

(A/C no. 8622)

A340-713-96

District Contact:
Mary Giraudo
Monterey Bay Unified APCD
(408) 647-9411  
Munters model IZS-D1500-TH Zeol VOC abatement unit consisting of two zeolite rotor concentrators in series followed by a 2 MMBtu/hr thermal oxidizer

150 lbm/day facility wide limit
(Control efficiency of 98.5%)
       
Georgia Pacific

Marquip laminator limited to 300,000 gal/yr adhesives
10/31/95

(A/C no. C-2005-8-0)

A340-706-96

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
Low-VOC adhesives

34.2 lbm/day
       
Texaco Refining and Marketing, Inc.

18,000 gal/min induced-draft evaporative cooling tower
1/19/96

(A/C no. S-33-353-0)

A350-704-96

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
LEL meter installed in head space of cooling tower for detection of VOCs

18.1 lbm/day
(Equivalent to 88% control)
      Munters cellular-type D-15 drift eliminator

30.2 lbm/day
(Equivalent to 75% control)
Paramount Farms

Fruit-roll manufacturing operation, including mixing room with three mixers for mash production processing at a rate of 86,000 lbm/hr mash with an ethanol content of 1.08% by wt.
12/15/95

(A/C no. S-2878-1-0)

A370-700-96

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
Wet scrubber utilizing water to control ethanol emissions from mixing room

0.08 lbm/hr
(Equivalent to 99% control)
       
Texaco Exploration and Production

4.20 MMBtu/hr guy-wire, vertical, 10ft.
3/12/96

(A/C no. S-1132-15-0 &S-1132-19-0)

A350-699-96

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
Kaldair Coanda-effect, electronic ignition

0.088 lbm/MMBtu
5% opacity
Kaldair Coanda-effect, electronic ignition

0.068 lbm/MMBtu
     
Community Recycling and Resource Recovery, Inc.

Composting and screening operations for "green waste" materials (i.e., tree clippings, trimmings, etc.) at a rate of 75 tons per hour
4/16/96

(A/C no. S-2905-1-0)

A410-697-96

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
        Maintenance of minimum moisture content of 25% using water suppressant when necessary to reduce visible emissions below 5% opacity

0.008 lbm/ton
5% opacity
Recot, Inc.

0.5 MMBtu/hr dry-air ambient cooler on tortilla chip line with an output of 3300 lbm/hr
10/31/95

(A/C no. S-2076-21-0)

A370-696-96

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
        High-velocity dust filter

0.16 lbm/hr
0.12 lbm/MMBtu
Recot, Inc.

Steam-heated conditioning units (fryer and de-oiler) on tortilla chip line with an output of 3300 lbm/hr; oven/fryer/de-oiler united rated at 7.5 MMBtu/hr
10/31/95

(A/C no. S-2076-21-0)

A370-695-96

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
        Oil mist eliminator to remove oily particles

0.04 lbm/hr for fryer
0.30 lbm/hr for de-oiler
Recot, Inc.

One 7.5 MMBtu/hr tortilla chip oven on a tortilla chip line witn an output of 3300 lbm/hr
10/31/95

(A/C no. S-2076-21-0)

A370-694-96

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
  Use of clean-burning fuel, such as natural gas with LPG backup fuel

0.100 lbm/MMBtu for natural gas
0.151 lbm/MMBtu for LPG
Use of clean-burning fuel, such as natural gas with LPG backup fuel

0.0006 lbm/MMBtu for natural gas
0.0166 lbm/MMBtu for LPG
  Use of clean-burning fuel, such as natural gas with LPG backup fuel

0.012 lbm/MMBtu
Berry Seed and Feed

24 ton/hr Magnum model 20x44 grain grinder
4/15/96

(A/C no. N-1758-28-0)

A370-691-96

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
        P&F model JT 6-42-355 baghouse with fabric filters

0.0067 lbm/ton of grain processed
Valley Seed Growers
Bean Dept.

14,440 cubic ft. methyl bromide fumigation chamber processing 180,000 lbm/day
2/20/96

(A/C no. 1335-4-0)

A370-690-96

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
No control

43 lbm/day
       
Four Bar C Farms, Inc.

Natural gas-fired dehydrator tunnel with 1.0 MMBtu/burner
3/28/96

(A/C no. C-0001-3-1)

A310-689-96

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
  No control

0.06 lbm/MMBtu
     
San Diego Unified Port District

Methyl bromide fruit fumigation using up to 1000 lbm/day methyl bromide
1/26/95

(App. no. 940532)

A370-675-96

District Contact:
Lorenzo Alejandria
San Diego Co. APCD
(619)694-3322  
Control of methyl bromide with Bromosorb Systems with halozites beds

No limit
(Expected control efficiency of 90%)
       
Gold Hills Nut Company

Almond sizing operation, including LMC West Mark 400 and LMC West
Mark 500 gravity tables, and LMC 7296 destoner processing 10 tons per hour almond meats
6/15/95

(A/C no. N-3290-2-0)

A370-662-95

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
        LMC model LP-252 reverse air fabric filter baghouse

25.8 lbm/day
(Equivalent to 0.129 lbm/ton of almond meats.
Nichols Pistachio

Pistachio precleaning operation processing 350 tons per day in-hull pistachios
1/30/95

(A/C no. C-862-3-2)

A370-661-95

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
        1D-3D cyclone

0.005 gr/dscf
Deckers

Sandal shoe manufacturing operation with three conveyorized assembly lines producing 750 pairs of shoes per hour and using 158 gallons of glue per day
5/11/95

(A/C no. ATC-9391)

A340-660-95

District Contact:
Steve Sterner
Santa Barbara Co. APCD
(805) 961-8886
sterners@sbcapcd.org
Assembly line capture hood with induced air flow at 6,000 scfm and interfacial velocity at opening of 75 ft/min. Air ducted to catalytic oxidizer

99% capture efficiency and 95% by wt. destruction efficiency
       
AgFibers, Incorporated

Fiber separation operation (897 electric hp total), including 3.0 MMBtu/hr natural-gas burner for material drying. 72 tons raw material processed per day. LPG backup fuel.
6/30/95

(A/C no. S-2802-2-0)

A370-655-95

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
  3.0 MMBtu/hr Eclipse Minnox low-NOx burner 75 hp fan

1.7 lbm/day
(Equivalent to 0.024 lbm/MMBtu or 20 ppmv at 3% oxygen)
    Saunco model 12-SFLB-196 Arr. Ill pulse jet-type baghouse with 196 polyester bags having 3,920 ft.2 filter area followed by 1D-3D cyclones (common baghouse serves combustion and non-combustion PM sources

40.5 lb/day
(Equil. to .007 gr/dscf)
Elegant Entry Door Manufacturing

Wood processing equipment manufacturing using 100 board feet/day
5/16/95

(A/C no. N-3319-2-0)

A400-652-95

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
        Quinones Manufacturing and Erectors Dura-Q baghouse

99% control efficiency
Semi Tropic Co-op, Inc.

10 foot Hi-Slip dryer with 6 MMBtu/hr LPG-fired Beltwide burner
6/23/95

(A/C no. S-877-1-8)

A370-649-95

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
  Emissions controlled through the use of "clean fuel" only

14.4 lbm/day
(Equivalent to
30 ppmvd at 3% oxygen or 0.1 lbm/MMBtu
     
Monarch Nut

Pistachio nut drying operation processing 480,000 lbm pistachios/day with natural gas-fired Farm Fan model 420-J crop dryer
4/14/95

(A/C no. S-130-1-1)

A370-648-95

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
  Natural gas-fired burner

13.7 lbm/day
(Equivalent to 0.083 lbm/MMBtu)
     
Fluid Containment, Inc.

Fiberglass utility pole manufacturing operation using 6,000 lbm resin per day, including mandrels, exhaust hood, wet saws, wet sanding machine, and a permit-exempt 5 MMBtu/hr boiler.
5/4/95

(A/C no. S-1810-6-0)

A410-644-95

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
Low VOC/monomer resins (no more than 35% monomer by weight), and non-VOC-containing cleanup solvent

48 lbm/day
       
Unocal/Fresno County Gas Production

Natural gas-fired glycol reboiler limited to 27 MMscf/day production gas throughput
12/7/94

(A/C no. C-1659-82)

A350-640-95

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(559) 230-5909  
Still column combuster (thermal oxidizer)

3.0 lbm/day
       
The Strip Shop

Custom made strip dip tank and flow/scrub tray with enclosed solvent return tank limited to using 794 gal/yr of methylene chloride
5/12/94

(A/C no. 901032

A340-632-95

District Contact:
Laura Yannayon
San Diego Co. APCD
(619) 694-3326  
Equipment modification reducing surface area, housekeeping practices, vapor collection system, and enclosed solvent return tanks

No limit
(Emission level of 21.5 lbm/day)

T-BACT for methylene chloride
       
ARCO

CQC kiln pilot project with waste-heat boiler using waste heat from rotary kiln for heating coke. Kiln is fired on process gas.
9/21/92

(App. no. 272153)

A310-628-94

District Contact:
Linda Basilio
South Coast AQMD
(209) 396-3156
lbasilio@aqqmd.gov
  Urea injection using NALCO Fuel Tech NOx-out process

No limit 173
     
California Cotton Fumgation Company

Three methyl bromide fumigation chambers
10/20/92

(App. no. 244059)

A370-611-94

District Contact:
Ron Lem
South Coast AQMD
(909) 396-2654
rlem@aqmd.gov
Prefilter, ultraviolet, oxidation, scrubber, and carbon adsorption

95% control efficiency
       
Watson Laboratories, Inc.

ARC Machine Co. transdermal coating (used for timed release of drugs) and laminating machine
2/12/93

(App. no. 273215)

A410-609-94

District Contact:
Alfonso Baez
South Coast AQMD
(909) 396-2516
abaez@aqmd.gov
Brule Incinerators, Inc. afterburner

95% destruction efficiency
       
California Synfuels Research Corp.

288 MMBtu/hr hydrogen purged fuel and natural gas-fired PSA hydrogen reformer furnace
10/05/1993

(A/C # S-0286-0005-0)
A430-603-93

District Contact:
Tom Goff
San Joaquin Valley Unified APCD
(805) 862-5200  
  Selas low-NOx burners and PSA hydrogen purge gas recycle

249 lbs/day
     
McGhan Medical

Silicone-based medical device manufacturing
11/19/93

(A/C no. 9130)

A410-602-93

District Contact:
Michael Goldman
Santa Barbara Co. APCD
(805) 961-8821
goldmanm@sbcapcd.org
Demtroi Systems no. 1600 recuperative thermal oxidizer

98.5% destruction efficiency
       
Kaweah Container, Inc.

Cardboard box manufacturing machine tool; ink and adhesives use limited to 50 and 25 gal/day, respectively
10/4/93

(A/C no. S-165-2-1)

A340-601-93

District Contact:
Tom Goff
San Joaquin Valley Unified APCD
(805) 862-5200  
Low-VOC inks and adhesives (less than 0.05 lbm VOC/gal)

No limit
       
Fertech Enviro Systems, Inc.

Soil remediation on site using
30 MMBtu/hr Cedarapids model 6422 rotary dryer; Hauck model Beta BBL-1112
25 MMBtu/hr after-burner; both units fired on natural gas
11/29/93

(A/C no. S-2330-1-0)

A430-599-93

District Contact:
Tom Goff
San Joaquin Valley Unified APCD
(805) 862-5200  
25MMBtu/hr gas-fired Cedarapids model no. 121.520 afterburner

0.07 lbm/ton
No control

0.12 lbm/MMBtu
    Cedarapids model no. 3520 pulse-jet baghouse with 224 fiberglass bags 10 ft long by 6 inches in diameter

0.09 lbm/ton
Louisiana-Pacific

Non-condensible gas handling system partially feeding to foul condensate stripper; steam stripping of condensates containing sulfides and methanol followed by afterburner; the operations are at a Kraft pulp mill
10/18/93

(A/C no. 263)

A400-598-93

District Contact:
Bob Clark
North Coast Unfied APCD
(707) 443-3093  
    Caustic scrubbing with sodium hydroxide

12.3 lbm/hr
99% control
   
Mobil Exploration and Production U.S., Inc.

69801 gal sand basin for sand discharged from heater treater
10/26/93

(A/C no. S-1511-670-0)

A350-597-93

District Contact:
Tom Goff
San Joaquin Valley Unified APCD
(805) 862-5200  
Sunscreen tarp cover, except during maintenance

13.2 lbm/day
       
Alcoa Electron Packaging

Electronic component manufacturing line (ceramic chip manufacturer), including, two Hirano tape casters for 4 ft. wide tapes; rated capacity of 4350 scfm
7/10/91

(App. no. 890086)

A410-591-93

District Contact:
Lorenzo Alejandria
San Diego Co. APCD
(619) 694-3322  
Two (2) Anguil 900 cfm catalytic oxidizers for adhesive sprayer

98.8% efficiency limit

Dual Airex roto incinerator with backup Airex incinerator (each 4800 cfm) for casting line

87 ppmvd
       
Goldfoil Manufacturing

Film coating line rated at
6,000 scfm
12/6/89

(App. no. 880896)

A340-588-93

District Contact:
Stan Romelczyk
San Diego Co. APCD
(619) 694-3308  
Boart Industies thermal oxidizer

90% control efficiency
       
Kraft General Foods, Inc.

15 MMBtu/hr gas-fired Niro model F-5600 filtermat dryer producing whey concentrate from the drying of whey (permitting action to convert boiler use from turkey processing to cheese production)
4/26/93

(A/C no. S-0843-0010-00)

A370-585-93

District Contact:
Tom Goff
San Joaquin Valley Unified APCD
(805) 862-5200  
  Maxon low NOx burner

32 ppmvd at 3% oxygen
0.04 lbm/MMBtu
    Filtermat spray dryer with product separation cyclones and wet scrubber

0.133 lbm/ton
Criterion Catalyst Co.

Micro-Pulverizer Model 60 ACM catalyst grinder with rated input of 2000 lbm/hr and storage silos (inlet PM is 95% PM10)
11/4/92

(A/C no. 9450)

A410-584-93

District Contact:
Thu Bui
Bay Area AQMD
(415) 749-5119  
        Four Micro-Pulsaire baghouses with 3000 acfm flow rates

0.006 gr./dscf
Gleanings for the Hungry

Expansion of sulfur dioxide fumigation to 70,000 lbm fruit per cycle (Pure sulfur dioxide gas is applied to fruit prior to drying)
6/3/93

(A/C no. S-422-1-1)

A370-580-93

District Contact:
Tom Goff/Doug Ray
San Joaquin Valley Unified APCD
(805) 862-5200  
    Caustic scrubber

0.25 lbm/hr
98.75% control
   
Lucas Film, Ltd

Lipsner Smith Co. model no. CF-3000-MKV film cleaning system using 180 gal of methyl cloroform per year and processing
8000 feet of film per gallon of solvent
4/29/93

(A/C no. 9942)

A340-577-93

District Contact:
Craig Ullery
Bay Area AQMD
(415) 749-4718  
Enclosed film cleaning system with refrigerated chiller operating at no more than 35 F

2000 lbm/yr
(Estimated control efficiency of 90%)
       
Bidart Brothers

Cold storage SO2 fumigation of table grapes
6/8/93

(A/C S-535-4-0)

A370-573-93

District Contact:
Tom Goff
San Joaquin Valley Unified APCD
(805) 862-5200  
    Balanced application of gaseous SO2 (also called total or full utilization method)

97.5 % control efficiency
30 ppm
   
Pacific Coast Fumigation

Methyl bromide fumigation chamber limited to 1000 cf/min and 5 batches per day
10/30/91

(App. no. 255953 thru -56)

A570-561-92

District Contact:
Henrique Nascimento
South Coast AQMD
(909) 396-2519
hnascimento@aqmd.gov
Thermal oxidizer and lime reactor

30 lbm/day
      Baghouse

2 lbm/day
Airco Coating Technology

Custom wipe cleaning operation with 100 gal/yr maximum solvent usage
4/28/92

(A/C no. 8650)

A340-539-92

District Contact:
Alex Saschin
Bay Area AQMD
(415) 749-4713  
Solvent to be stored in closed containers

No limit
       
National Semiconductor

Semiconductor fabrication area with photo-resist maskant and developer operations
4/10/92

(A/C no. 7129)

A410-533-92

District Contact:
Craig Ullery
Bay Area AQMD
(415) 749-4718  
REECO Fume incinerator

10 ppmv
0.985
       
Solectron Corporation

Relocation of wave solder systems with foam fluxers having 3.35 gal flux capacity and a net solvent usage of 6000 gal/yr
4/2/92

(App. no. 8337)

A410-531-92

District Contact:
Carol Allen
Bay Area AQMD
(415) 749-4702  
Calgon Vapor Pac-10 carbon absorption unit

10 ppmv at 10,000 cfm
90% control efficiency
       
Certified Grocers of California, Ltd.

10 MMBtu/hr APV Lanham Bakery Oven fired on natural gas
9/14/90

(App. nos. 228274 and 219899)

A370-504-92

District Contact:
Minh Pham
South Coast AQMD
(909) 396-2613
mpham@aqmd.gov
CSM Systems Inc. catalytic afterburner

95% control efficiency
       
General Electric Aircraft Engines

Downdraft tables at vented to dust collector on which fiberglass parts are manually sanded and finished.
10/22/91

(A/C nos. 0012023, 0012025, and 0012026)

A410-485-91

District Contact:
Tom Paxson
Kern Co. APCD
(805) 861-2593  
        Fabricmax fabric dust collector

0.02 lbm/hr
(Expected control efficiency of 99.7%)
Xerox Corporation

Semiconductor manufacturing: photolithographic station, solvent cleaning station, and four wave soldering machines
3/13/90

(App. nos. 178490-91, 177299, 177300, 177676-77, and 202335)

A400-462-90

District Contact:
Knut Beruldsen
South Coast AQMD
(909) 396-2605
kberuldsen@aqmd.gov
Packed bed type thermal oxidizer; four electrostatic precipitators to catch waste solvent and oily flux material

No limit
(Estimated control efficiency of 90%)
       
WITCO
(Golden Bear Division)

554-barrel, steam jacketed blending tank with 30 hp motor used for manufacturing plasticized asphalt
1/23/90

(A/C no. 2026054)

A350-461-90

District Contact:
Tom Goff
Kern Co. APCD
(now the San Joaquin Valley Unified APCD)
(805) 862-5200  
Lean oil absorber followed by carbon canister

99.9% control
0.07 lbm/hr
       
Gold Bond Bldg. Prod.

Riser maker, chopper and conveyors
7/22/87

(App. no. 155860)

A410-250-87

District Contact:
Fred del Rosario
South Coast AQMD
(909) 396-2663  
        Dust collector

No limit
(Estimated emission rate of 0.48 lbm/day)
Fontana Paper Mills, Inc.

14300 lbm/hr roofing felt dip-type saturator line
8/26/87

(App. no. 123531)

A410-248-87

District Contact:
Permit Services
South Coast AQMD
(909) 396-3385  
        Heaf filter

No limit
(Estimated emission rate of 19.8 lbm/day)
Stepan Chemical Co.

16,920-gallon, molten sulfur storage tank
1/20/87

(App no. 150941)

A360-212-87

District Contact:
Permit Services
South Coast AQMD
(909) 396-3385  
    Caustic scrubber

No limit
(Estimated emission control of 99.5%)
   
Color America

Textile processing system
2/23/87

(App. no. 151991)

A410-180-87

District Contact:
Fred del Rosario
South Coast AQMD
(909) 396-2663  
        Electrostatic precipitator

No limit
(Estimated control efficiency of 99%)
PMC Specialties Group Productol Div.

Dryer/crystallizer for phenol (normally vented to atmosphere)
2/23/87

(App No.: 147720)

A360-177-87

District Contact:
S. Tan
South Coast AQMD
(909) 396-2000
stan@aqmd.gov
Natural gas-fired incinerator

Estimated Efficiency of 90%
       
Chevron-Gaviota

Vacuum truck usage marine loading terminal
2/6/86

(A/C no. 5704)

A350-132-86

District Contact:
Bill Master
Santa Barbara Co. APCD
(805) 961-8800  
    Vent exhaust thru caustic scrubber for H2S control

80% control
   
California Almond Growers Exchange

Almond shell & hull pneumatic separator w/cartridge type reverse airpulse jet baghouse
1/24/86

(A/C No.: 3080004)

A370-105-86

District Contact:
Tom Goff
(805) 862-5200
San Joaquin Valley Unified APCD
(599) 230-5900  
        Baghouse

No limit
Ultrasystems/Chinese Camp

26 MW EPI wood-fired fluid bed combustor power plant
8/9/85

(A/C # 55-8986

A310-100-85

District Contact:
E. Withycombe
Tuolumne County APCD
(209) 533-5693  
  Thermal deNOx/fluid bed; VOC and CO fluid bed/combustion controls

0.14 lb/MMBtu
    TSP - Multiclone/ESP

0.0470 lb/MMBtu
Manville Forest Products

Renzmann solvent degreaser and Renzmann solvent distillation unit
11/6/85

(A/C # 0030008 & 0030009)

A340-99-85

District Contact:
Tom Paxson
Kern County APCD
(Now the San Joaquin Valley Unified APCD)
(805) 861-3682  
Vent degreaser & distiller to existing recirculation incinerators//see remarks

95.6 control efficiency
0.5 lbm/hr
       
Eimac/Varian Fab Center

Detrex VS-8DOE vapor degreaser using 1,1,1 trichloroethane
7/12/85

(A/C # 30832)

A340-083-85

District Contact:
Craig Ullery
Bay Area AQMD
(415) 771-6000  
Use of freeboard chiller (above cooling coils) to provide blanket of cool air to reduce emission of TCE

33% control efficiency
       
VAFB's STS Program

Fuel servicing and deservicing system at V23 launch pad
4/8/85

(A/C # 5626)
A420-082-85

District Contact:
Mr. Grapple
Santa Barbara County APCD
(805) 961-8800  
Scrubber using water as the absorbing medium

1 lb/hr
       
VAFB's STS Program

Orbiter & payload fuel deservicing system at V19 OMCF
4/8/85

(A/C # 5625)

A420-081-85

District Contact:
Mr. Grapple
Santa Barbara County APCD
(805) 961-8800  
AVEL Corp. scrubber using water as the adsorbing medium

0.1 lb/hr
       
VAFB's STS Program

Hydrazine (NH2-NH2) fuel servicing and deservicing system at V23 STS payload preparation room
4/8/85

(A/C # 5624)

A420-080-85

District Contact:
Mr. Grapple
Santa Barbara County APCD
(805) 961-8800  
AVEL Corp. scrubber using water as the adsorbing medium

0.1 lb/hr
       
VAFB's STS Program

19888.3 lb/day nitrogen tetroxide deservicing system at V23 Orbiter maintenance and checkout facility
4/8/85

(A/C # 5622)

A420-079-85

District Contact:

Mr. Grapple
Santa Barbara County APCD
(805) 961-8800  
  Martin Mavietto Corp. scubber using a 25% aqueoues solution of sodium hydroxide as the absorbing medium

1 lb/hr
     
VAFB's STS Program

19888.3 lb/day nitrogen tetroxide servicing and deservicing system at V23, Launch Pad
4/8/85

(A/C # 5621)

A420-078-85

District Contact:

Mr. Grapple
Santa Barbara County APCD
(805) 961-8800  
  Martin Mavietto Corp. scubber using a 25% aqueoues solution of sodium hydroxide as the absorbing medium

1 lb/hr
     
Louisiana Pacific Coporation

611,248 lbm wood fiber/hr steam heated wood fiber dryer for hardboard manufacturing
5/10/85

(A/C # LPO-75-04-AC

A400-077-85

District Contact:
Graig Gilmour
Butte County AQMD
(530) 891-2882  
        MEC Corporation high efficiency cyclonic collectors

25.34 lb/hr
0.032 gr/scf
Continental Can Company

2-piece aluminum can lines
3/15/85

(A/C # 30129)

A340-074-85

District Contact:
Judy Cutino
Bay Area AQMD
(415) 771-6000  
Direct flame afterburner controlling pin ovens, inside bake oven and fugitive emissions from spray machines

26 tons/yr
95% control efficiency (afterburner)
       
Warren Petroleum

Modification of existing CO2 removal system: addition of four membrane modules
4/10/85

(A/C # 2023010A)

A350-072-85

District Contact:
Tom Paxon
San Joaquin Valley Unified APCD
(former Kern County APCD)
(805) 861-3682  
Inspection and maintenance of fugitive emission sources

0.40 lbm/day (value)
0.24 lbm/day (flange)
       
Bohemia, Inc.

600,000 board foot per day planner mill
12/26/84

(A/C # A/C-84-15)

A400-067-85

District Contact:
D.W. Dixon
Placer County APCD
(530) 889-7130  
        Clarke cyclone and baghouse

0.00144 gr/dscf
Granite Construction Company

150 hp Teltsmite cone crusher
1/29/85

(A/C # 1008010C)

A390-063-85

District Contact:
Tom Paxson
San Joaquin Valley Unified APCD
(former Kern County APCD)
(805) 861-3682  
        Tee Jet (spray nozzles) water spray and tarp shroud at discharge

No limit
Commerce Refuse-to-Energy

Waste-to-Energy facility; 330 tons per day mass-burn water-wall incinerator
5/8/84

(A/C # 103650)

A320-056-84

District Contact:
Knut Beruldsen
South Coast AQMD
(909) 396-3136
kberuldsen@aqmd.gov
  Thermal de-NOx and combustion modifications

40 lb/hr
Spray dryer

11 lb/hr
  Combustion control and baghouse

6 lb/hr
Hoover Universal

1300 lb/hr foam polyurethene autobody set maufacture
7/11/84

(A/C # 29799)

410-050-84

District Contact:
Steve Hill
Bay Area AQMD
(415) 771-6000 x212  
No control        
Moblie Oil

Two well vent vapor control systems
9/1/84

(A/C # 4011216 and 4011217)

A350-046-84

District Contact:
Tom Paxon
San Joaquin Valley Unified APCD
(former Kern County APCD)
(805) 861-3682  
McGill Inc. incinerate well head non-condensible gases for HC control

99% control efficiency
       
Gabriel Power Co.

Biomass Burner
8/18/84

(A/C # 40102610101-144)

A320-043-84

District Contact:
George Heinen
San Joaquin Valley Unified APCD
(599) 230-5909
george.heinen@valleyair.org
    Red Crown baghouse and scrubber

0.0247 lb/meg btu input
   
Shell California Production, Inc. (North Belnidye Dehy Facility)

3,000 bbl/day crude oil dehydration and storage with truck loading rack
5/25/84

(A/C # 4012304A)

A350-42-84

District Contact:
Tom Paxon
San Joaquin Valley Unified APCD
(former Kern County APCD)
(805) 861-3682  
Vapor control system connedted to process, storage and truck loading equipment

177.2 lbm/day
       
Cannery - Stanislaus Food

125,000 lb/hr Ward-Schmid Nebraska model NS-G-101 steam boiler
3/8/84

(A/C # 3-019-04)

A310-037-84

District Contact:
Mark Boese
San Joaquin Valley Unified APCD
(Stanislaus County APCD)

(209) 571-6908  
  Oxygen trim control, Hague International MJ-900-D burner with flue gas recirculation and staged combustion

65 ppm @ 3% O2
     
Ultrasystems-Blue Lake

162 MMBtu/hr wood-waste fueled steam/electric generation plant with cascade type fuel dryer
1/12/84

A/C # HAC-129)

A320-029-84

District Contact:
Chuck Sassenrath
North Coast Unified AQMD
(707) 443-3093  
        Multiclones and granular bed electro-scrubber for particulate//furnace combustion design for CO, NOx, and HC

0.045 lb/MMBtu
Aeroject Strategic Propulsion

Chemical Process
4/1/83

(A/C # 7542)

A430-028-83

District Contact:
Robert Knight
Sacarmento Metropolitan AQMD
(916) 874-4800  
VIC regenerative carbon adsorber

45 lb/day
       
American Lignite Cogeneration

240 MMBtu/hr Recirculating fluid bed combustion boiler with baghouse
12/21/83

(A/C # No A/C)

A310-025-83

District Contact:
Earl Withycombe
Amador County APCD
(209) 274-2407  
  Low bed temp, staged combustion

61.40 lbm/hr
247.97 tons/yr
Limestone injection into fluid bed

65.34 lbm/hr
262.43 tons/yr
  Multiclone/Baghouse

7.88 lbm/hr
31.77 tons/yr
Hayfork Cogeneration Project

236 MMBtu/hr wood waste-fired steam/electric generation plant
12/14/83

(A/C # TAC-012

A320-024-83

District Contact:
Chuck Sassenrath
(707) 443-3093  
Furnace combustion design

0.07 lb/MMBtu
Furnace combustion design

0.15 lb/MMBtu
Furnace combustion modification

0.35 lb/MMBtu
  Multiclones and ESP

0.04 lb/MMBtu
Pacific Refinery Modification

2.75 MMBtu/hr refinery hydrogen reformer furnace, H-4011
9/28/83

(A/C # 29180)

A310-022-80

District Contact:
Leonard Clayton
Bay Area AQMD
(415) 771-6000  
  Ammonia injection and selective catalytic reduction unit

20 ppm @ 3% O2
85% control efficiency
     
Pacific Refinery Modifications

Refinery fuel gas system
9/28/83

(A/C # 29180)

A350-021-83

District Contact:
Leonard Clayton
Bay Area AQMD
(415) 771-6000  
    Diglycolamine absorbing system for H2S removal

50 ppm H2S in fuel gas
   
Stecher - Travng - Schmidt

Varnisher drying oven, dry-sys, on varnisher 261
10/8/82

(A/C #28246)

A340-015-82

District Contact:
Ellen Linder
Bay Area AQMD
(415) 771-6000  
Hirt model FLX-7M fume incinerator

90 % overall control efficiency
97% (in-out of incinerator)
       
Mr. Spa's, Inc.

Gel coat & polyester resin application- manufacture of fiberglass spas
9/8/83

(A/C # 1240-1)

A340-013-83

District Contact

Keith Doval
Ventura County APCD
(805) 654-2664  
Increase styrene content in gel coat (to 41%)//Use of filler material in resin//vapor suppressant agents in resin

63% reduction
       
Exxon Co. USA - Benicia

Refinery Process Furnace
12/10/80

(A/C # 27599)

A310-010-80

District Contact:
Leonard Clayton
Bay Area AQMD
(415) 771-6000  
  Low-Nox burners and thermal de-NOx

40 ppmvd @ 3% O2
70% control efficiency
     
H.S. Crocker Co. Printing

6 COLDR 64" Printing Press
3/21/83

(A/C # 28709)

A340-008-83

District Contact:
Mohamad Mdazed
Bay Area AQMD
(415) 771-6000  
Limit on VOC centent of inks

2.5 lb VOC/day
       
Gazette Press Printing

Two 12950 cfm Tec Printing System drying ovens
12/20/82

(A/C # 28925)

A340-007-82

District Contact:
Mohamad Mdazed
Bay Area AQMD
(415) 771-6000  
Katec, TVA-812 fume incinerator

95% control efficiency
       
American Metal Decorating Co.

Paint coating line for metal parts
3/7/80

(A/C # 27361)

A340-006-80

District Contact:
John Phillips
Bay Area AQMD
(415) 771-6000  
CE Air Preheater Cor-Pak fume incinerator

87% control efficiency
       
Time Oil Co. (Loading Rack)

One million gallons per day gasoline bulk loading rack
12/23/80

(A/C # 27611)

A350-004-82

District Contact:
Dave Dixon
Bay Area AQMD
(415) 771-6000  
McGill activated carbon adsorption system with two beds. Automatically timed desorption cycle

98.6% control efficiency
       
TOSCO Corp. Hydrotreating Unit

5 hp or larger centerifugal pump seals
2/19/82

(A/C # 27769)

A350-003-82

District Contact:
Jim Karas
Bay Area AQMD
(415) 771-6000  
Double mechanical seals with a oil seal

500 ppm
       
CAPCOA BACT Clearinghouse Source Category - 200 Miscellaneous

BEST AVAILABLE CONTROL TECHNOLOGY DETERMINATION DATA SUBMITTED TO THE
CALIFORNIA AIR POLLUTION CONTROL OFFICERS ASSOCIATION BACT CLEARINGHOUSE

Equipment or Process: NO CODE ATTRIBUTED YET Revision: 3.0
Equipment Rating: Date 07/18/00
Project Name & Description A/C Issue Date & ARB File No. BACT AND CORRESPONDING EMISSION CONTROL LEVELS
VOC/HC NOx SOx CO PM/PM10
Chevron Lube Oil Project

Four refinery process furnaces manifolded to common exhaust stack F-7, F-8, F-9, F-10
4/8/82

(A/C # 27797)

A310-002-82)

District Contact:
John Sawnson
Bay Area AQMD
(415) 771-6000  
  One selective catalytic reduction unit for four furnaces and lo-NOx burners

No limit
     
CAPCOA BACT Clearinghouse Source Category - 999 NO CODE ATTRIBUTED YET